EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimal Distribution Network Reconfiguration Using Particle Swarm Optimization-Simulated Annealing: Adaptive Inertia Weight Based on Simulated Annealing

Franklin Jesus Simeon Pucuhuayla, Dionicio Zocimo Ñaupari Huatuco, Yuri Percy Molina Rodriguez, Jhonatan Reyes Llerena

Energies · 17.10.2025 · 18 (20) · 5483

DOI: 10.3390/en18205483 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 17.10.2025. Verfasst von Franklin Jesus Simeon Pucuhuayla und 3 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The reconfiguration of distribution networks plays a crucial role in minimizing active power losses and enhancing reliability, but the problem becomes increasingly complex with the integration of distributed generation (DG). Traditional optimization methods and even earlier hybrid metaheuristics often suffer from premature convergence or require problem reformulations that compromise feasibility. To overcome these limitations, this paper proposes a novel hybrid algorithm that couples Particle Swarm Optimization (PSO) with Simulated Annealing (SA) through an adaptive inertia weight mechanism derived from the Lundy–Mees cooling schedule. Unlike prior hybrid approaches, our method directly addresses the original non-convex, combinatorial nature of the Distribution Network Reconfiguration (DNR) problem without convexification or post-processing adjustments. The main contributions of this study are fourfold: (i) proposing a PSO-SA hybridization strategy that enhances global exploration and avoids stagnation; (ii) introducing an adaptive inertia weight rule tuned by SA, more effective than traditional schemes; (iii) applying a stagnation-based stopping criterion to speed up convergence and reduce computational cost; and (iv) validating the approach on 5-, 33-, and 69-bus systems, with and without DG, showing robustness, recurrence rates above 80%, and low variability compared to conventional PSO. Simulation results confirm that the proposed PSO-SA algorithm achieves superior performance in both loss minimization and solution stability, positioning it as a competitive and scalable alternative for modern active distribution systems.

Zitieren

APA

Pucuhuayla, F. J. S., Huatuco, D. Z. Ñ., Rodriguez, Y. P. M., & Llerena, J. R. (2025). Optimal Distribution Network Reconfiguration Using Particle Swarm Optimization-Simulated Annealing: Adaptive Inertia Weight Based on Simulated Annealing. Energies, 18(20), 5483. https://doi.org/10.3390/en18205483

Vancouver

Pucuhuayla FJS, Huatuco DZÑ, Rodriguez YPM, Llerena JR. Optimal Distribution Network Reconfiguration Using Particle Swarm Optimization-Simulated Annealing: Adaptive Inertia Weight Based on Simulated Annealing. Energies. 2025;18(20):5483. doi:10.3390/en18205483

BibTeX
@article{Pucuhuayla2025,
  author = {Pucuhuayla, Franklin Jesus Simeon and Huatuco, Dionicio Zocimo Ñaupari and Rodriguez, Yuri Percy Molina and Llerena, Jhonatan Reyes},
  title = {Optimal Distribution Network Reconfiguration Using Particle Swarm Optimization-Simulated Annealing: Adaptive Inertia Weight Based on Simulated Annealing},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {20},
  pages = {5483},
  doi = {10.3390/en18205483}
}