EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Online Junction Temperature Measurement for Power MOSFETs Using the Body Diode Under Varying Forward Currents

Xueli Zhu, Yajie Huang, Donglai Zhang, Yuepeng Zhang, Jun Wu, Bowen Jiang, Linzhong Xia, Bo Gao, Changwei Lv

Energies · 23.09.2025 · 18 (19) · 5045

DOI: 10.3390/en18195045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 23.09.2025. Verfasst von Xueli Zhu und 8 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Projects of Shenzhen University of Information Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Power metal-oxide-semiconductor field-effect transistors (MOSFETs) provide numerous advantages and are widely utilized in various power circuits. The junction temperature plays a critical role in determining the reliability, performance, and operational lifetime of power MOSFETs. Therefore, accurate monitoring of the junction temperature of power MOSFETs is essential to ensure the safe operation of power circuit systems. In bridge or motor drive circuits, MOSFETs often operate in a freewheeling state via the body diode, where the freewheeling current is typically variable. The proposed method for junction temperature measurement utilizes the body diode and is designed to accommodate varying forward currents. It also accounts for the temperature-dependent ideality factor to improve measurement accuracy. By integrating the forward voltage and forward current of the body diode, this approach reduces the required sampling frequency. To validate the method’s effectiveness, three representative types of power MOSFETs, a Si MOSFET (IRF520), a SiC MOSFET (C2M0080120D), and an aerospace-grade radiation-hardened MOSFET (RSCS25045T1RH), were used to measure junction temperatures before and after irradiation. Following ideality factor correction, the maximum absolute error compared to reference measurements from thermocouples and a thermal imager remained within 2 K across the temperature range of 300 K to 420 K. Experimental results confirm the feasibility of the proposed method.

Förderung

  • National Natural Science Foundation of China
  • Projects of Shenzhen University of Information Technology

Zitieren

APA

Zhu, X., Huang, Y., Zhang, D., Zhang, Y., Wu, J., Jiang, B., Xia, L., Gao, B., & Lv, C. (2025). Online Junction Temperature Measurement for Power MOSFETs Using the Body Diode Under Varying Forward Currents. Energies, 18(19), 5045. https://doi.org/10.3390/en18195045

Vancouver

Zhu X, Huang Y, Zhang D, Zhang Y, Wu J, Jiang B, et al. Online Junction Temperature Measurement for Power MOSFETs Using the Body Diode Under Varying Forward Currents. Energies. 2025;18(19):5045. doi:10.3390/en18195045

BibTeX
@article{Zhu2025,
  author = {Zhu, Xueli and Huang, Yajie and Zhang, Donglai and Zhang, Yuepeng and Wu, Jun and Jiang, Bowen and Xia, Linzhong and Gao, Bo and Lv, Changwei},
  title = {Online Junction Temperature Measurement for Power MOSFETs Using the Body Diode Under Varying Forward Currents},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {19},
  pages = {5045},
  doi = {10.3390/en18195045}
}