EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental Study on Wind Load of Large-Span Flexible Photovoltaic Structure Considering Different Tilt Angles

Bin Zhang, Shidong Nie, Min Liu, Honghao Zhang, Yifan Wang, Xinling Fan, Dongdong Zhang, Huaizhong Huang

Energies · 10.09.2025 · 18 (18) · 4820

DOI: 10.3390/en18184820 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 10.09.2025. Verfasst von Bin Zhang und 7 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technology Project of Power Construction Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to their light weight, low stiffness, and large range of tilt angle changes, flexible-support photovoltaic structures are highly sensitive to wind loads. Therefore, it is necessary to study the wind load characteristics under large tilt angles and determine reasonable design wind loads. This paper investigates the wind load characteristics of large-span flexible-support PV arrays with different tilt angles through wind tunnel pressure measurements. The results indicate that, in terms of mean wind pressure coefficient, 0° and 180° are the most unfavorable wind direction angles. The first row at the edge of the array is the most unfavorable location, and its shape coefficient is recommended to be 1.3 (for wind pressure) or −1.25 (for wind suction), with subsequent rows of PV panels being appropriately reduced based on this value. The tilt angle of the PV panels significantly affects the shading effect, and under large tilt angle conditions, there is an abrupt drop in the mean wind pressure coefficient and fluctuating wind pressure coefficient of the second row facing the wind. Under large tilt angles, the critical wind direction angles for local extreme wind loads are within the ranges of 15–45° and 135–165°, and the most unfavorable locations occur in the corner areas at the edges of the array. Local extreme wind loads should be considered in the design.

Förderung

  • Technology Project of Power Construction Corporation of China

Zitieren

APA

Zhang, B., Nie, S., Liu, M., Zhang, H., Wang, Y., Fan, X., Zhang, D., & Huang, H. (2025). Experimental Study on Wind Load of Large-Span Flexible Photovoltaic Structure Considering Different Tilt Angles. Energies, 18(18), 4820. https://doi.org/10.3390/en18184820

Vancouver

Zhang B, Nie S, Liu M, Zhang H, Wang Y, Fan X, et al. Experimental Study on Wind Load of Large-Span Flexible Photovoltaic Structure Considering Different Tilt Angles. Energies. 2025;18(18):4820. doi:10.3390/en18184820

BibTeX
@article{Zhang2025,
  author = {Zhang, Bin and Nie, Shidong and Liu, Min and Zhang, Honghao and Wang, Yifan and Fan, Xinling and Zhang, Dongdong and Huang, Huaizhong},
  title = {Experimental Study on Wind Load of Large-Span Flexible Photovoltaic Structure Considering Different Tilt Angles},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {18},
  pages = {4820},
  doi = {10.3390/en18184820}
}
Kostenlos starten →