EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements

Hao Sheng, Siqi Zhang, Tianqi Zhao, Jing Hao, Qi Li, Guangming Xin, Rui Chen, Xiaofei Wang, Xiang Ren

Energies · 11.08.2025 · 18 (16) · 4267

DOI: 10.3390/en18164267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 11.08.2025. Verfasst von Hao Sheng und 8 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Electric Power Research Institute State Grid Jibei Electric Power Company Limited.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The large-scale integration of renewable energy and the high penetration of power electronic devices have led to a significant reduction in system inertia and short-circuit capacity. This is particularly manifested in the form of insufficient multiple renewable energy stations short-circuit ratio (MRSCR) and transient overvoltage issues following severe disturbances such as AC and DC faults, which greatly limit the power transfer capability of large renewable energy bases. To effectively mitigate these challenges, this paper proposes an optimal synchronous condenser deployment method tailored for large-scale renewable energy bases. The proposed mathematical model supports a hybrid centralized and distributed configuration of synchronous condensers with various capacities and manufacturers while considering practical engineering constraints such as short-circuit ratio, transient overvoltage, and available bays in renewable energy stations. A practical decomposition and iterative computation strategy is introduced to reduce the computational burden of transient stability simulations. Case studies based on a real-world system verify the effectiveness of the proposed method in determining the optimal configuration of synchronous condensers. The results demonstrate significant improvements in grid strength (MRSCR) and suppression of transient overvoltages, thereby enhancing the stability and transfer capability of renewable energy bases in weak-grid environments.

Förderung

  • Electric Power Research Institute State Grid Jibei Electric Power Company Limited

Zitieren

APA

Sheng, H., Zhang, S., Zhao, T., Hao, J., Li, Q., Xin, G., Chen, R., Wang, X., & Ren, X. (2025). Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements. Energies, 18(16), 4267. https://doi.org/10.3390/en18164267

Vancouver

Sheng H, Zhang S, Zhao T, Hao J, Li Q, Xin G, et al. Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements. Energies. 2025;18(16):4267. doi:10.3390/en18164267

BibTeX
@article{Sheng2025,
  author = {Sheng, Hao and Zhang, Siqi and Zhao, Tianqi and Hao, Jing and Li, Qi and Xin, Guangming and Chen, Rui and Wang, Xiaofei and Ren, Xiang},
  title = {Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {16},
  pages = {4267},
  doi = {10.3390/en18164267}
}
Kostenlos starten →