Fachartikel in der Zeitschrift Energies, online erschienen am 21.06.2025. Verfasst von Guoqing He und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Zhejiang Natural Science Foundation of China, The Center for Balance Architecture of Zhejiang University.
Abstract (Originalsprache)
Double skin facade (DSF) is an energy-efficient solution for glazing facades. However, previous studies have reported inconsistent findings regarding thermal comfort in naturally ventilated DSF buildings. To examine this issue, this study evaluated airflow velocities in naturally ventilated DSF buildings during transition seasons through a comparative study approach. A full-scale box-type DSF room and a traditional window-wall room were simultaneously monitored in a laboratory building under real climatic conditions, with indoor environmental parameters recorded for 10 days. Airflow sensation surveys complemented the physical measurements to evaluate perceived comfort. The results showed that the DSF room consistently exhibited lower air velocities (≤0.2 m/s) compared to the traditional room, demonstrating minimal response to wind conditions related to its small openings (opening ratio of 4.7%) and increased flow resistance from the dual-layer structure of the DSF. Under unfavorable wind conditions, the DSF room demonstrated higher ventilation rates due to the enhanced stack effect. However, this advantage had a negligible effect on the thermal comfort vote for the indoor temperature range (26 °C to 28 °C). These findings highlight the climate-dependent performance of DSFs: while advantageous for thermal comfort in cooler climates, they may lead to reduced thermal comfort in warm and hot climates due to low indoor airflow velocities. Future work could include the optimization of DSF opening configurations to enhance wind-driven ventilation while maintaining stack ventilation benefits.
Förderung
- The Zhejiang Natural Science Foundation of China
- The Center for Balance Architecture of Zhejiang University
Zitieren
APA
He, G., Fan, Z., Meng, Y., Yao, L., & Ye, C. (2025). An Experimental Study of Wind-Driven Ventilation with Double Skin Facade During Transition Seasons. Energies, 18(13), 3249. https://doi.org/10.3390/en18133249
Vancouver
He G, Fan Z, Meng Y, Yao L, Ye C. An Experimental Study of Wind-Driven Ventilation with Double Skin Facade During Transition Seasons. Energies. 2025;18(13):3249. doi:10.3390/en18133249
BibTeX
@article{He2025,
author = {He, Guoqing and Fan, Zhewen and Meng, Yuan and Yao, Linfeng and Ye, Changqing},
title = {An Experimental Study of Wind-Driven Ventilation with Double Skin Facade During Transition Seasons},
journal = {Energies},
year = {2025},
volume = {18},
number = {13},
pages = {3249},
doi = {10.3390/en18133249}
}
EUVIMED