Fachartikel in der Zeitschrift Energies, online erschienen am 18.05.2025. Verfasst von Yongjia Li und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, 75th Batch of General Projects, Postdoctoral Fellowship Program of CPSF.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydropower’s ability to start up and shut down quickly, combined with its flexible regulation characteristics, effectively alleviates frequency fluctuations caused by new energy sources, ensuring the safe and stable operation of the power system. However, during peak-frequency regulation tasks, the transition processes associated with the startup, shutdown, and load changes introduce frequent shocks to subsystems such as the hydro-turbine, governor, and diversion systems. These shocks pose significant challenges to the safe and stable operation of hydropower plants. Therefore, this study constructs a coupled hydraulic–mechanical–electrical model that incorporates the diversion system, hydro-turbine, governor, generator, and load, based on operational data from a real-world hydropower plant in China. The load increase transition process is selected for parameter sensitivity analysis to evaluate the influence of various structural, operational, and control parameters on unit stability and to identify key parameters affecting stability. The results indicate that the initial load exhibits the highest sensitivity to inversion power peak and rotational speed overshoot, with sensitivity values of 0.14 and 0.0038, respectively. The characteristic water head shows the greatest sensitivity to the inversion power peak time and rotational speed peak time, with values of 0.31 and 0.43, respectively. Additionally, the integration gain significantly influences the rotational speed rise time, with a sensitivity value of 0.30. These findings provide a theoretical basis for optimizing the parameter selection in hydropower plants.

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation, 75th Batch of General Projects
  • Postdoctoral Fellowship Program of CPSF
  • Shaanxi Province Postdoctoral Research Project

Zitieren

APA

Li, Y., Guo, Y., Li, M., Lei, L., Hu, H., Chen, D., Zhao, Z., & Xu, B. (2025). Multi-Objective Sensitivity Analysis of Hydraulic–Mechanical–Electrical Parameters for Hydropower System Transient Response. Energies, 18(10), 2609. https://doi.org/10.3390/en18102609

Vancouver

Li Y, Guo Y, Li M, Lei L, Hu H, Chen D, et al. Multi-Objective Sensitivity Analysis of Hydraulic–Mechanical–Electrical Parameters for Hydropower System Transient Response. Energies. 2025;18(10):2609. doi:10.3390/en18102609

BibTeX
@article{Li2025,
  author = {Li, Yongjia and Guo, Yixuan and Li, Ming and Lei, Liuwei and Hu, Huaming and Chen, Diyi and Zhao, Ziwen and Xu, Beibei},
  title = {Multi-Objective Sensitivity Analysis of Hydraulic–Mechanical–Electrical Parameters for Hydropower System Transient Response},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {10},
  pages = {2609},
  doi = {10.3390/en18102609}
}
Kostenlos starten →