Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation

Yuheng Hu, Hongzhou Zhang, Zhenwei Luo, Yupeng Zhou, Guoshun Yuan

Energies · 02.05.2025 · 18 (9) · 2330

DOI: 10.3390/en18092330 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 02.05.2025. Verfasst von Yuheng Hu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Program of XPCC, Xinjiang Production and Construction Corps New Energy Industry Innovation Research Institute Construction Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fixed double-row photovoltaic (PV) arrays are susceptible to wind-induced damage, while their wind load characteristics remain inadequately investigated. This study employs computational fluid dynamics (CFD) simulations to systematically analyze wind load behavior under varying operational conditions, aiming to identify critical scenarios and structural vulnerabilities. First, the validity of the CFD methodology was verified through direct comparison between wind tunnel pressure measurements of an isolated PV module and corresponding numerical simulations. Subsequently, scaled PV array models were constructed to replicate practical engineering configurations, enabling a systematic evaluation of wind direction effects on mean net wind pressure coefficients and three-component force coefficients. Finally, surface wind pressure distribution patterns were examined for four representative wind angles (0°, 45°, 135°, 180°). Results demonstrate that edge-positioned modules exhibit maximum mean net wind pressure coefficients and three-component force coefficients under oblique wind angles (45° and 135°), which are identified as the most critical operational conditions. In contrast, minimal wind loads were observed at a 90° wind angle, indicating an optimal orientation for array installation. Additionally, significantly higher surface wind pressure coefficients were recorded for edge modules under oblique winds (45°/135°) compared to both interior modules and other wind angles. It was found through the study that under upwind conditions (0–90°), the lower-row components are capable of withstanding greater wind loads, whereas under downwind conditions (90–180°), an increase in the loads exerted on the upper-row components was observed.

Förderung

  • Science and Technology Program of XPCC
  • Xinjiang Production and Construction Corps New Energy Industry Innovation Research Institute Construction Project

Zitieren

APA

Hu, Y., Zhang, H., Luo, Z., Zhou, Y., & Yuan, G. (2025). Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation. Energies, 18(9), 2330. https://doi.org/10.3390/en18092330

Vancouver

Hu Y, Zhang H, Luo Z, Zhou Y, Yuan G. Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation. Energies. 2025;18(9):2330. doi:10.3390/en18092330

BibTeX
@article{Hu2025,
  author = {Hu, Yuheng and Zhang, Hongzhou and Luo, Zhenwei and Zhou, Yupeng and Yuan, Guoshun},
  title = {Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {9},
  pages = {2330},
  doi = {10.3390/en18092330}
}