Reliability of High-Frequency Earth Meters in Measuring Tower-Footing Resistance: Simulations and Experimental Validation

Renan Segantini, Rafael Alipio, José O. S. Paulino

Energies · 11.04.2025 · 18 (8) · 1959

DOI: 10.3390/en18081959 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 11.04.2025. Verfasst von Renan Segantini und 2 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES), National Council for Scientific and Technological Development (CNPq).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a comprehensive assessment of the accuracy of high-frequency (HF) earth meters in measuring the tower-footing ground resistance of transmission line structures, combining simulation and experimental results. The findings demonstrate that HF earth meters reliably estimate the harmonic grounding impedance (R25kHz) at their operating frequency, typically 25 kHz, for a wide range of soil resistivities and typical span lengths. For the analyzed tower geometries, the simulations indicate that accurate measurements are obtained for adjacent span lengths of approximately 300 m and 400 m, corresponding to configurations with one and two shield wires, respectively. Acceptable errors below 10% are observed for span lengths exceeding 200 m and 300 m under the same conditions. While the measured R25kHz does not directly represent the resistance at the industrial frequency, it provides a meaningful measure of the grounding system’s impedance, enabling condition monitoring and the evaluation of seasonal or event-related impacts, such as damage after outages. Furthermore, the industrial frequency resistance can be estimated through an inversion process using an electromagnetic model and knowing the geometry of the grounding electrodes. Overall, the results suggest that HF earth meters, when correctly applied with the fall-of-potential method, offer a reliable means to assess the grounding response of high-voltage transmission line structures in most practical scenarios.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)
  • National Council for Scientific and Technological Development (CNPq)

Zitieren

APA

Segantini, R., Alipio, R., & Paulino, J. O. S. (2025). Reliability of High-Frequency Earth Meters in Measuring Tower-Footing Resistance: Simulations and Experimental Validation. Energies, 18(8), 1959. https://doi.org/10.3390/en18081959

Vancouver

Segantini R, Alipio R, Paulino JOS. Reliability of High-Frequency Earth Meters in Measuring Tower-Footing Resistance: Simulations and Experimental Validation. Energies. 2025;18(8):1959. doi:10.3390/en18081959

BibTeX
@article{Segantini2025,
  author = {Segantini, Renan and Alipio, Rafael and Paulino, José O. S.},
  title = {Reliability of High-Frequency Earth Meters in Measuring Tower-Footing Resistance: Simulations and Experimental Validation},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {8},
  pages = {1959},
  doi = {10.3390/en18081959}
}
Kostenlos starten →