The Effect of Facade Orientation on the Electrical Performance of a BIPV System: A Case Study in João Pessoa, Brazil

Michelli Mayara de Medeiros Gomes, Renan Douglas Lopes da Silva Cavalcante, Oswaldo Hideo Ando Junior, Claudio Del Pero, João Alves de Lima, Taynara Geysa Silva do Lago

Energies · 11.02.2025 · 18 (4) · 829

DOI: 10.3390/en18040829 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 11.02.2025. Verfasst von Michelli Mayara de Medeiros Gomes und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal University of Paraíba, and by the FAPESQ agency (Fundação de Apoio à Pesquisa do Estado da Paraíba) throughout the project, FACEPE agency (Fundação de Amparo a Pesquisa de Pernambuco) throughout the project, Brazilian National Council for Scientific and Technological Development (CNPq).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photovoltaic solar energy has emerged as a vital solution in energy transition, especially in buildings with building-integrated photovoltaic (BIPV) systems. This study evaluated a BIPV system in João Pessoa, Brazil, using PVsyst 7.4 software for simulations in 2023 and experimental tests in 2024 to compare real and simulated energy values injected into the grid. The experiments were conducted in April, June, July, and August, covering seasonal variations. The east and west orientations showed the best performance, with annual production of 65.5 and 81.6 kWh, respectively, due to the balanced solar irradiance. Conversely, the north and south orientations generated less electricity, with 51.3 and 42.1 kWh, respectively, due to lower direct solar exposure. The average injected energy was 0.2445 to 0.2530 kWh/day in April, 0.2851 to 0.2470 kWh/day in June, 0.2816 to 0.2400 kWh/day in July, and 0.1556 to 0.1700 kWh/day in August. Performance ratios were 44.3% for the north, 44.4% for the south, 47.4% for the east, and 56.8% for the west, highlighting the impact of orientation. It is concluded that the east and west facades are more suitable for BIPV systems in João Pessoa, emphasizing the importance of local factors in optimizing urban energy efficiency.

Förderung

  • Federal University of Paraíba, and by the FAPESQ agency (Fundação de Apoio à Pesquisa do Estado da Paraíba) throughout the project
  • FACEPE agency (Fundação de Amparo a Pesquisa de Pernambuco) throughout the project
  • Brazilian National Council for Scientific and Technological Development (CNPq)

Zitieren

APA

Gomes, M. M. D. M., Cavalcante, R. D. L. D. S., Junior, O. H. A., Pero, C. D., Lima, J. A. D., & Lago, T. G. S. D. (2025). The Effect of Facade Orientation on the Electrical Performance of a BIPV System: A Case Study in João Pessoa, Brazil. Energies, 18(4), 829. https://doi.org/10.3390/en18040829

Vancouver

Gomes MMDM, Cavalcante RDLDS, Junior OHA, Pero CD, Lima JAD, Lago TGSD. The Effect of Facade Orientation on the Electrical Performance of a BIPV System: A Case Study in João Pessoa, Brazil. Energies. 2025;18(4):829. doi:10.3390/en18040829

BibTeX
@article{Gomes2025,
  author = {Gomes, Michelli Mayara de Medeiros and Cavalcante, Renan Douglas Lopes da Silva and Junior, Oswaldo Hideo Ando and Pero, Claudio Del and Lima, João Alves de and Lago, Taynara Geysa Silva do},
  title = {The Effect of Facade Orientation on the Electrical Performance of a BIPV System: A Case Study in João Pessoa, Brazil},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {4},
  pages = {829},
  doi = {10.3390/en18040829}
}
Kostenlos starten →