EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads

Nicholas Truster, Jamie S. Ervin, Abdeel Roman, Jeff Monfort

Energies · 17.12.2024 · 17 (24) · 6347

DOI: 10.3390/en17246347 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 17.12.2024. Verfasst von Nicholas Truster und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Air Force Research Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As avionics become more power dense, electronic device cooling has become a significant barrier to aircraft integration. A mechanically pumped two-phase loop (MPTL) is a thermal subsystem that enables near isothermal evaporator operation, which is desirable for electronics cooling. The goal of this study was to integrate an MPTL with a pressure-controlled accumulator and model a predictive control technique to demonstrate improvements for transient, isothermal evaporator operation for MPTLs under pulsed evaporator heat loads. The model predictive controller enables active control of MPTL compressible volume, which has not been demonstrated for pulsed evaporator heat loads. Experimental data were collected to validate a representative numerical model. A pressure-controlled accumulator was added to an MPTL to experimentally characterize the system thermodynamic response for three pulsed evaporator heat loads. Two statistical methods were used to assess the numerical model agreement with the experimental results. Under pulsed evaporator heat loads, the mean percent error agreed within 3.45% and the mean average percent error agreed within 0.74% for the three pulsed evaporator heat loads. Finally, a traditional proportional–integral (PI) controller and an advanced model predictive controller were developed and integrated into the validated numerical model. Both control methods were evaluated for an expanded set of evaporator heat load profiles to analyze transient behavior. For evaporator heat profiles with high heat transfer rates, the model predictive controller can maintain a target ±2 K refrigerant temperature at the evaporator exit throughout the evaporator heat load duration, whereas the PI-controlled MPTL cannot. Through this work, active control of a pressure-controlled accumulator within an MPTL is shown to improve refrigerant isothermal (±2 K) operation when compared to a traditional control technique.

Förderung

  • Air Force Research Laboratory

Zitieren

APA

Truster, N., Ervin, J. S., Roman, A., & Monfort, J. (2024). Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads. Energies, 17(24), 6347. https://doi.org/10.3390/en17246347

Vancouver

Truster N, Ervin JS, Roman A, Monfort J. Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads. Energies. 2024;17(24):6347. doi:10.3390/en17246347

BibTeX
@article{Truster2024,
  author = {Truster, Nicholas and Ervin, Jamie S. and Roman, Abdeel and Monfort, Jeff},
  title = {Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {24},
  pages = {6347},
  doi = {10.3390/en17246347}
}