EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response

Tiannan Ma, Lilin Peng, Gang Wu, Danhao Chen, Xin Zou

Energies · 28.11.2024 · 17 (23) · 6000

DOI: 10.3390/en17236000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 28.11.2024. Verfasst von Tiannan Ma und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of State Grid Sichuan Electric Power Company.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Integrated energy systems (IESs) have been implemented with the objective of enhancing the efficiency of energy utilization and facilitating the sustainable transition of society and energy systems. To further explore the multi-energy coupling capacity and carbon reduction potential of the IESs, this study presents the design of an integrated cold-electricity-heat energy system (ICEHS) with advanced adiabatic compressed air energy storage (AA-CAES). AA-CAES has the capacity to not only store and release electric energy, but also to provide cold and heat energy, which makes it an ideal choice for this application. The main work of this study is fourfold: (1) the energy hub concept is employed to describe the energy transformations within AA-CAES, thereby reducing the modeling complexity; (2) integrated demand response (IDR) for cooling, heating, and electric loads, including shiftable loads, adjustable loads, interruptible loads, and replaceable loads, is considered; (3) Latin hypercubic sampling in conjunction with K-means clustering is employed to address the issue of source-load uncertainty; and (4) an ICEHS operation optimization model is developed with the objective of minimizing the daily operating cost, where the possible cost terms include energy purchase cost, operation and maintenance cost, demand response cost, and carbon emission cost. A typical community integrated energy system is employed as an illustrative example, and four different scenarios are established to validate the effectiveness of the proposed model. The results indicate that AA-CAES and IDR can effectively reduce the daily operating cost and carbon emissions of an ICEHS. In comparison to the scenario that did not incorporate AA-CAES and IDR, the daily operating cost and carbon emissions are reduced by 4.8% and 10.3%, respectively.

Förderung

  • Science and Technology Project of State Grid Sichuan Electric Power Company

Zitieren

APA

Ma, T., Peng, L., Wu, G., Chen, D., & Zou, X. (2024). Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response. Energies, 17(23), 6000. https://doi.org/10.3390/en17236000

Vancouver

Ma T, Peng L, Wu G, Chen D, Zou X. Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response. Energies. 2024;17(23):6000. doi:10.3390/en17236000

BibTeX
@article{Ma2024,
  author = {Ma, Tiannan and Peng, Lilin and Wu, Gang and Chen, Danhao and Zou, Xin},
  title = {Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {23},
  pages = {6000},
  doi = {10.3390/en17236000}
}
Kostenlos starten →