Comprehensive Investigation of the Thermal Performance of an Electrically Heated Double-Glazed Window: A Theoretical and Experimental Approach
Energies · 06.09.2024 · 17 (17) · 4491
DOI: 10.3390/en17174491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 06.09.2024. Verfasst von Borys Basok und 5 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation.
Abstract (Originalsprache)
The thermal performance of windows is an important area of research to reduce the energy consumption of buildings and improve indoor comfort. The application of innovative glazing technologies can improve the energy performance of windows and transparent facades, resulting in significant energy savings. This paper presents research results on the energy performance of electrically heated windows. A comprehensive CFD and experimental analysis of the heat transfer processes in a window space depending on the size, power, and location of an electric heater was performed. The convective gas flows in the gas gaps and in the boundary layer were also analysed, and it is shown that a window with an electric heater can reduce the energy consumption of a room by 10–12%. This study is a pilot study to assess the feasibility and cost-effectiveness of electric local heating of a window or facade to minimise heat loss before full-scale implementation. The results of numerical modelling and experimental studies confirm the potential of the new technologies.
Förderung
- National Research Foundation
Zitieren
APA
Basok, B., Pavlenko, A., Novikov, V., Koshlak, H., Ciosek, A., & Moroz, M. (2024). Comprehensive Investigation of the Thermal Performance of an Electrically Heated Double-Glazed Window: A Theoretical and Experimental Approach. Energies, 17(17), 4491. https://doi.org/10.3390/en17174491
Vancouver
Basok B, Pavlenko A, Novikov V, Koshlak H, Ciosek A, Moroz M. Comprehensive Investigation of the Thermal Performance of an Electrically Heated Double-Glazed Window: A Theoretical and Experimental Approach. Energies. 2024;17(17):4491. doi:10.3390/en17174491
BibTeX
@article{Basok2024,
author = {Basok, Borys and Pavlenko, Anatoliy and Novikov, Volodymyr and Koshlak, Hanna and Ciosek, Anita and Moroz, Maryna},
title = {Comprehensive Investigation of the Thermal Performance of an Electrically Heated Double-Glazed Window: A Theoretical and Experimental Approach},
journal = {Energies},
year = {2024},
volume = {17},
number = {17},
pages = {4491},
doi = {10.3390/en17174491}
}
EUVIMED