Intelligent Substation Noise Monitoring System: Design, Implementation and Evaluation
Energies · 22.06.2024 · 17 (13) · 3083
DOI: 10.3390/en17133083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 22.06.2024. Verfasst von Wenchen Chen und 5 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Fund of State Key Laboratory of Power Grid Environmental Protection.
Abstract (Originalsprache)
In recent years, the State Grid of China has placed significant emphasis on the monitoring of noise in substations, driven by growing environmental concerns. This paper presents a substation noise monitoring system designed based on an end-network-cloud architecture, aiming to acquire and analyze substation noise, and report anomalous noise levels that exceed national standards for substation operation and maintenance. To collect real-time noise data at substations, a self-developed noise acquisition device is developed, enabling precise analysis of acoustic characteristics. Moreover, to subtract the interfering environmental background noise (bird/insect chirping, human voice, etc.) and determine if noise exceedances are originating from substation equipment, an intelligent noise separation algorithm is proposed by leveraging the convolutional time-domain audio separation network (Conv-TasNet), dual-path recurrent neural network (DPRNN), and dual-path transformer network (DPTNet), respectively, and evaluated under various scenarios. Experimental results show that (1) deep-learning-based separation algorithms outperform the traditional spectral subtraction method, where the signal-to-distortion ratio improvement (SDRi) and the scale-invariant signal-to-noise ratio improvement (SI-SNRi) of Conv-TasNet, DPRNN, DPTNet and the traditional spectral subtraction are 12.6 and 11.8, 13.6 and 12.4, 14.2 and 12.9, and 4.6 and 4.1, respectively; (2) DPTNet and DPRNN exhibit superior performance in environment noise separation and substation equipment noise separation, respectively; and (3) 91% of post-separation data maintains sound pressure level deviations within 1 dB, showcasing the effectiveness of the proposed algorithm in separating interfering noises while preserving the accuracy of substation noise sound pressure levels.
Förderung
- Open Fund of State Key Laboratory of Power Grid Environmental Protection
Zitieren
APA
Chen, W., Liu, Y., Gao, Y., Hu, J., Liao, Z., & Zhao, J. (2024). Intelligent Substation Noise Monitoring System: Design, Implementation and Evaluation. Energies, 17(13), 3083. https://doi.org/10.3390/en17133083
Vancouver
Chen W, Liu Y, Gao Y, Hu J, Liao Z, Zhao J. Intelligent Substation Noise Monitoring System: Design, Implementation and Evaluation. Energies. 2024;17(13):3083. doi:10.3390/en17133083
BibTeX
@article{Chen2024,
author = {Chen, Wenchen and Liu, Yingdong and Gao, Yayu and Hu, Jingzhu and Liao, Zhenghai and Zhao, Jun},
title = {Intelligent Substation Noise Monitoring System: Design, Implementation and Evaluation},
journal = {Energies},
year = {2024},
volume = {17},
number = {13},
pages = {3083},
doi = {10.3390/en17133083}
}