EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermal Performance Design and Analysis of Reversed Brayton Cycle Heat Pumps for High-Temperature Heat Supply

Jin-Seo Kim, In-Ho Chung, Tong-Seop Kim, Chan-Ho Song

Energies · 15.06.2024 · 17 (12) · 2953

DOI: 10.3390/en17122953 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 15.06.2024. Verfasst von Jin-Seo Kim und 3 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Institute of Machinery and Materials, Korea government(MSIT).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study examined the performance of reversed Brayton cycle heat pumps to supply heat above 300 °C. The aim was to overcome the current temperature limitations faced by heat pump technology in industrial heat supply sectors by examining the viability of the reversed Brayton cycle. In particular, the effects of the operating conditions on the cycle performance, such as the waste and return heat temperatures, were analyzed through thermal performance analysis. The reversed Brayton cycle heat pumps showed improved performance over conventional vapor compression cycle heat pumps when a heat supply above 215 °C was required. Furthermore, integrating additional heat exchangers into the cycle configuration was proposed in this study as a method to enhance waste heat utilization and recover unused heat from industrial processes. By incorporating preheating and recuperated cycles, these modifications broaden the operational range under the same operating conditions. They also improve the coefficient of performance (COP) of the reference cycle by up to 23% and 27.4%, respectively. This study explored the potential of reversed Brayton cycle heat pumps to supply heat above 300 °C and provided fundamental guidelines for the efficient design and operation of reversed Brayton cycle heat pumps. The results are expected to enhance our understanding of the performance characteristics of reversed Brayton cycle heat pump technology and expand its use as an alternative to fossil-fuel-based heat supply systems.

Förderung

  • Korea Institute of Machinery and Materials
  • Korea government(MSIT)

Zitieren

APA

Kim, J., Chung, I., Kim, T., & Song, C. (2024). Thermal Performance Design and Analysis of Reversed Brayton Cycle Heat Pumps for High-Temperature Heat Supply. Energies, 17(12), 2953. https://doi.org/10.3390/en17122953

Vancouver

Kim J, Chung I, Kim T, Song C. Thermal Performance Design and Analysis of Reversed Brayton Cycle Heat Pumps for High-Temperature Heat Supply. Energies. 2024;17(12):2953. doi:10.3390/en17122953

BibTeX
@article{Kim2024,
  author = {Kim, Jin-Seo and Chung, In-Ho and Kim, Tong-Seop and Song, Chan-Ho},
  title = {Thermal Performance Design and Analysis of Reversed Brayton Cycle Heat Pumps for High-Temperature Heat Supply},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {12},
  pages = {2953},
  doi = {10.3390/en17122953}
}
Kostenlos starten →