Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 17.04.2024. Verfasst von Michael Bachseitz und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bayerische Forschungsstiftung.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For the energy transition in the residential sector, heat pumps are a core technology for decarbonizing thermal energy production for space heating and domestic hot water. Electricity generation from on-site photovoltaic (PV) systems can also contribute to a carbon-neutral building stock. However, both will increase the stress on the electricity grid. This can be reduced by using appropriate control strategies to match electricity consumption and production. In recent years, artificial intelligence-based approaches such as reinforcement learning (RL) have become increasingly popular for energy-system management. However, the literature shows a lack of investigation of RL-based controllers for multi-family building energy systems, including an air source heat pump, thermal storage, and a PV system, although this is a common system configuration. Therefore, in this study, a model of such an energy system and RL-based controllers were developed and simulated with physical models and compared with conventional rule-based approaches. Four RL algorithms were investigated for two objectives, and finally, the soft actor–critic algorithm was selected for the annual simulations. The first objective, to maintain only the required temperatures in the thermal storage, could be achieved by the developed RL agent. However, the second objective, to additionally improve the PV self-consumption, was better achieved by the rule-based controller. Therefore, further research on the reward function, hyperparameters, and advanced methods, including long short-term memory layers, as well as a training for longer time periods than six days are suggested.

Förderung

  • Bayerische Forschungsstiftung

Zitieren

APA

Bachseitz, M., Sheryar, M., Schmitt, D., Summ, T., Trinkl, C., & Zörner, W. (2024). PV-Optimized Heat Pump Control in Multi-Family Buildings Using a Reinforcement Learning Approach. Energies, 17(8), 1908. https://doi.org/10.3390/en17081908

Vancouver

Bachseitz M, Sheryar M, Schmitt D, Summ T, Trinkl C, Zörner W. PV-Optimized Heat Pump Control in Multi-Family Buildings Using a Reinforcement Learning Approach. Energies. 2024;17(8):1908. doi:10.3390/en17081908

BibTeX
@article{Bachseitz2024,
  author = {Bachseitz, Michael and Sheryar, Muhammad and Schmitt, David and Summ, Thorsten and Trinkl, Christoph and Zörner, Wilfried},
  title = {PV-Optimized Heat Pump Control in Multi-Family Buildings Using a Reinforcement Learning Approach},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {8},
  pages = {1908},
  doi = {10.3390/en17081908}
}
Kostenlos starten →