Research on Insulation Configuration of 220 kV Bushing in High-Altitude Polluted Areas

Zhijin Zhang, Yuanpeng Zhang, Wei Xiao, Yong Sun, Xingliang Jiang

Energies · 29.03.2024 · 17 (7) · 1645

DOI: 10.3390/en17071645 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 29.03.2024. Verfasst von Zhijin Zhang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Science and Technology Projects of China Southern Power Grid Corporation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The external insulation strength of the power equipment sleeve in the substation and converter station will be reduced with the increase in altitude and atmosphere pollution. The weakness of external insulation seriously threatens the safe operation of electrical equipment. At present, there are few studies and conclusions that focus on the flashover characteristics of power equipment bushing in high-altitude polluted areas. Therefore, this paper takes the 220 kV voltage level bushing as the research object and studies the Alternating Current (AC) pollution flashover characteristics and lightning and switching impulse flashover characteristics at low pressure. The insulation configuration at high-altitude polluted areas is analyzed. Finally, the insulation configuration scheme, which is suitable for high-altitude polluted areas, is proposed. The results show that the AC pollution flashover voltages of the bushing decrease with the decrease in the atmospheric pressure and the increase in the salt density as a power exponent function. The impulse flashover voltages also decrease with the decrease in the atmospheric pressure as a power exponent function. The atmospheric pressure/pollution impact characteristic index is related to the type of voltage, the value of the atmospheric pressure, and the value of the salt density. The test bushing does not meet the insulation configuration requirements in some high-altitude polluted areas. Through the analysis and calculation of the test results, the bushing insulation configuration scheme in high-altitude polluted areas is proposed. The research results can provide a reference for the external insulation design of bushings in substations and converter stations in high-altitude polluted areas.

Förderung

  • Key Science and Technology Projects of China Southern Power Grid Corporation

Zitieren

APA

Zhang, Z., Zhang, Y., Xiao, W., Sun, Y., & Jiang, X. (2024). Research on Insulation Configuration of 220 kV Bushing in High-Altitude Polluted Areas. Energies, 17(7), 1645. https://doi.org/10.3390/en17071645

Vancouver

Zhang Z, Zhang Y, Xiao W, Sun Y, Jiang X. Research on Insulation Configuration of 220 kV Bushing in High-Altitude Polluted Areas. Energies. 2024;17(7):1645. doi:10.3390/en17071645

BibTeX
@article{Zhang2024,
  author = {Zhang, Zhijin and Zhang, Yuanpeng and Xiao, Wei and Sun, Yong and Jiang, Xingliang},
  title = {Research on Insulation Configuration of 220 kV Bushing in High-Altitude Polluted Areas},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {7},
  pages = {1645},
  doi = {10.3390/en17071645}
}
Kostenlos starten →