Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 27.02.2024. Verfasst von Juan Carlos Huaquisaca Paye und 7 weiteren Autor:innen. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Energy Equatorial Group at the Research and Development, Pro-Rectory of Research and Post-Graduate Studies-PROPESP/UFPA.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detecting and locating high impedance faults (HIF) in overhead distribution networks (ODN) remains one of the biggest challenges for manufacturers and researchers due to the complexity of this phenomenon, where the electrical current magnitude is similar to that of the loads. To simulate HIF, the selection of the HIF model is important, because it has to correctly reproduce the characteristics of this phenomenon, so that it does not negatively influence the simulations results. Therefore, HIF models play a fundamental role in proposing solutions and validating the effectiveness of the proposed methods to detect and localize HIF in ODN. This paper presents a systematic review of HIF models. It is intended to facilitate the selection of the HIF model to be considered. The models are validated based on experimental data from medium voltage (MV) laboratories, specifically, recorded waveforms from two HIF tests conducted in an MV lab were analyzed and compared with three established HIF models. The efficacy of these models was assessed against MV lab test data to ensure a precise representation of both transient and steady-state conditions for fault conductance and current waveforms. The findings show that the two nonlinear resistor models better approximate the waveforms obtained in the experimental tests performed in this study.

Förderung

  • Energy Equatorial Group at the Research and Development
  • Pro-Rectory of Research and Post-Graduate Studies-PROPESP/UFPA

Zitieren

APA

Paye, J. C. H., Vieira, J. P. A., Tabora, J. M., Leão, A. P., Cordeiro, M. A. M., Junior, G. C., Morais, A. P. D., & Farias, P. E. (2024). High Impedance Fault Models for Overhead Distribution Networks: A Review and Comparison with MV Lab Experiments. Energies, 17(5), 1125. https://doi.org/10.3390/en17051125

Vancouver

Paye JCH, Vieira JPA, Tabora JM, Leão AP, Cordeiro MAM, Junior GC, et al. High Impedance Fault Models for Overhead Distribution Networks: A Review and Comparison with MV Lab Experiments. Energies. 2024;17(5):1125. doi:10.3390/en17051125

BibTeX
@article{Paye2024,
  author = {Paye, Juan Carlos Huaquisaca and Vieira, João Paulo A. and Tabora, Jonathan Muñoz and Leão, André P. and Cordeiro, Murillo Augusto M. and Junior, Ghendy C. and Morais, Adriano P. de and Farias, Patrick E.},
  title = {High Impedance Fault Models for Overhead Distribution Networks: A Review and Comparison with MV Lab Experiments},
  journal = {Energies},
  year = {2024},
  volume = {17},
  number = {5},
  pages = {1125},
  doi = {10.3390/en17051125}
}