Ground Resistance Estimation for a DC Converter Station: Theory versus Experiment

Samar Akef, Ahdab M. K. El-Morshedy, Mohamed M. Samy, Ahmed M. Emam, Hadeer H. El-Hawary

Energies · 06.02.2024 · 17 (4) · 765

DOI: 10.3390/en17040765 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 06.02.2024. Verfasst von Samar Akef und 4 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper is aimed at proposing a calculation model for the ground resistance of a grounding scheme servicing a high-voltage direct-current converter station. The method is based on the equivalence of current conduction and electric field from the grounding scheme through the surrounding medium. The grounding scheme is composed of three concentric ring electrodes supported by two horizontal conductors and eight vertical rods. The calculated ground resistance is 4.8 Ω against the experimental value of 5 Ω with an error of 4.2%. The calculated ground resistance value agrees reasonably well with that of 4.7 Ω as obtained using CYMGRD software (version 7.0). The calculated surface-potential values over the ground surface agreed reasonably well with those measured experimentally, with an average deviation not exceeding 6.5%. This study is designed to investigate how ground resistance is decreased by the increase in the scheme parameters, including the rods’ diameter and length, as well as the radius of the inner and outer rings. The dependency of the ground resistance on the soil type is also investigated.

Zitieren

APA

Akef, S., El-Morshedy, A. M. K., Samy, M. M., Emam, A. M., & El-Hawary, H. H. (2024). Ground Resistance Estimation for a DC Converter Station: Theory versus Experiment. Energies, 17(4), 765. https://doi.org/10.3390/en17040765

Vancouver

Akef S, El-Morshedy AMK, Samy MM, Emam AM, El-Hawary HH. Ground Resistance Estimation for a DC Converter Station: Theory versus Experiment. Energies. 2024;17(4):765. doi:10.3390/en17040765

BibTeX
@article{Akef2024,
  author = {Akef, Samar and El-Morshedy, Ahdab M. K. and Samy, Mohamed M. and Emam, Ahmed M. and El-Hawary, Hadeer H.},
  title = {Ground Resistance Estimation for a DC Converter Station: Theory versus Experiment},
  journal = {Energies},