Internal Arc Performance of Instrument Transformers Filled with Different Dielectric Liquids
Energies · 19.01.2024 · 17 (2) · 493
DOI: 10.3390/en17020493 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 19.01.2024. Verfasst von Ivan Mihoković und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Internal arc testing is still a controversial topic in the instrument transformer world. The main reason for that is the fact that even a fully successful test guarantees only a certain degree of transformer safety. Furthermore, the test does not cover a plethora of operational fault scenarios and has requirements which are not defined clearly enough. In addition, there are very few data available in the literature on the internal arc performance of alternative, biodegradable dielectric liquids. Some liquids (such as natural and synthetic esters) do inherently come with higher flash and fire points compared to conventional mineral oil, but there is insufficient test experience to corroborate the influence this high fire point has on the actual operation. Specifically, to the authors’ knowledge, internal arc tests on instrument transformers were never performed with biodegradable dielectric liquids, making the contributions of this paper a true world premiere. In short, this paper is intended to augment the existing standards, thus providing additional insight into how to test internal arc performance, what to look out for and what level of performance to expect, which is of broad interest to researchers, utility engineers and public alike.
Zitieren
APA
Mihoković, I., Rački, A., Žiger, I., & Plavec, E. (2024). Internal Arc Performance of Instrument Transformers Filled with Different Dielectric Liquids. Energies, 17(2), 493. https://doi.org/10.3390/en17020493
Vancouver
Mihoković I, Rački A, Žiger I, Plavec E. Internal Arc Performance of Instrument Transformers Filled with Different Dielectric Liquids. Energies. 2024;17(2):493. doi:10.3390/en17020493
BibTeX
@article{Mihokovi2024,
author = {Mihoković, Ivan and Rački, Anton and Žiger, Igor and Plavec, Eduard},
title = {Internal Arc Performance of Instrument Transformers Filled with Different Dielectric Liquids},
journal = {Energies},
year = {2024},
volume = {17},
number = {2},
pages = {493},
doi = {10.3390/en17020493}
}