Fault Detection and Localisation in LV Distribution Networks Using a Smart Meter Data-Driven Digital Twin
Energies · 30.11.2023 · 16 (23) · 7850
DOI: 10.3390/en16237850 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 30.11.2023. Verfasst von Mohamed Numair und 4 weiteren Autor:innen. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Energy Technology Partnership, Scottish Power Energy Networks.
Abstract (Originalsprache)
Modern solutions for precise fault localisation in Low Voltage (LV) Distribution Networks (DNs) often rely on costly tools such as the micro-Phasor Measurement Unit (μPMU), which is potentially impractical for the large number of nodes in LVDNs. This paper introduces a novel fault detection technique using a distribution network digital twin without the use of μPMUs. The Digital Twin (DT) integrates data from Smart Meters (SMs) and network topology to create an accurate replica. In using SM voltage-magnitude readings, the pre-built twin compiles a database of fault scenarios and matches them with their unique voltage fingerprints. However, this SM-based voltage-only approach shows only a 70.7% accuracy in classifying fault type and location. Therefore, this research suggests using the cables’ Currents Symmetrical Component (CSC). Since SMs do not provide direct current data, a Machine Learning (ML)-based regression method is proposed to estimate the cables’ currents in the DT. Validation is performed on a 41-node LV distribution feeder in the Scottish network provided by the industry partner Scottish Power Energy Networks (SPEN). The results show that the current estimation regressor significantly improves fault localisation and identification accuracy to 95.77%. This validates the crucial role of a DT in distribution networks, thus enabling highly accurate fault detection when using SM voltage-only data, with further refinements being conducted through estimations of CSC. The proposed DT offers automated fault detection, thus enhancing customer connectivity and maintenance team dispatch efficiency without the need for additional expensive μPMU on a densely-noded distribution network.
Förderung
- Energy Technology Partnership
- Scottish Power Energy Networks
Zitieren
APA
Numair, M., Aboushady, A. A., Arraño-Vargas, F., Farrag, M. E., & Elyan, E. (2023). Fault Detection and Localisation in LV Distribution Networks Using a Smart Meter Data-Driven Digital Twin. Energies, 16(23), 7850. https://doi.org/10.3390/en16237850
Vancouver
Numair M, Aboushady AA, Arraño-Vargas F, Farrag ME, Elyan E. Fault Detection and Localisation in LV Distribution Networks Using a Smart Meter Data-Driven Digital Twin. Energies. 2023;16(23):7850. doi:10.3390/en16237850
BibTeX
@article{Numair2023,
author = {Numair, Mohamed and Aboushady, Ahmed A. and Arraño-Vargas, Felipe and Farrag, Mohamed E. and Elyan, Eyad},
title = {Fault Detection and Localisation in LV Distribution Networks Using a Smart Meter Data-Driven Digital Twin},
journal = {Energies},
year = {2023},
volume = {16},
number = {23},
pages = {7850},
doi = {10.3390/en16237850}
}