Energy Performance of Room Air-Conditioners and Ceiling Fans in Mixed-Mode Buildings
Energies · 25.09.2023 · 16 (19) · 6807
DOI: 10.3390/en16196807 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 25.09.2023. Verfasst von Sriraj Gokarakonda und 3 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Friends of the Wuppertal Institute (Die Vereinigung der Freunde des Wuppertal Instituts), Wuppertal Institut für Klima, Umwelt.
Abstract (Originalsprache)
Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space cooling. However, there is little empirical evidence on the energy savings from using ceiling fans with Room Air-Conditioners (RACs). To address this gap, we analysed the energy performance of RACs with both fixed-speed compressors and inverter technology at different set-point temperatures and ceiling fan speed settings in 15 residential Mixed-Mode Buildings (MMBs) in India. Thermal comfort conditions (as predicted by the Indian Model for Adaptive Comfort-Residential (IMAC-R)) with minimum energy consumption were maintained at a set-point temperature (Tset) of 28 and 30 ∘C and a fan speed setting of one. Compared with a Tset of 24 °C, a Tset of 28 and 30 °C resulted in energy savings of 44 and 67%, respectively. With the use of RACs, a configuration with a minimum fan speed was satisfactory for an optimal use of energy and for maintaining the conditions of thermal comfort. In addition, RACs with inverter technology used 34–68% less energy than fixed-speed compressors. With the rising use of RACs, particularly in tropical regions, the study’s outcomes offer a significant potential for reducing space-cooling energy consumption and the resultant greenhouse gas (GHG) emissions.
Förderung
- Friends of the Wuppertal Institute (Die Vereinigung der Freunde des Wuppertal Instituts)
- Wuppertal Institut für Klima
- Umwelt
- Energie gGmbH
Zitieren
APA
Gokarakonda, S., Treeck, C. V., Rawal, R., & Thomas, S. (2023). Energy Performance of Room Air-Conditioners and Ceiling Fans in Mixed-Mode Buildings. Energies, 16(19), 6807. https://doi.org/10.3390/en16196807
Vancouver
Gokarakonda S, Treeck CV, Rawal R, Thomas S. Energy Performance of Room Air-Conditioners and Ceiling Fans in Mixed-Mode Buildings. Energies. 2023;16(19):6807. doi:10.3390/en16196807
BibTeX
@article{Gokarakonda2023,
author = {Gokarakonda, Sriraj and Treeck, Christoph van and Rawal, Rajan and Thomas, Stefan},
title = {Energy Performance of Room Air-Conditioners and Ceiling Fans in Mixed-Mode Buildings},
journal = {Energies},
year = {2023},
volume = {16},
number = {19},
pages = {6807},
doi = {10.3390/en16196807}
}
EUVIMED