EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monitoring and Analysis of the Operation Performance of Vertical Centrifugal Variable Frequency Pump in Water Supply System

Jianyong Hu, Chaohao Wang, Chengju Shan, Yunhui Guo

Energies · 05.06.2023 · 16 (11) · 4526

DOI: 10.3390/en16114526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 05.06.2023. Verfasst von Jianyong Hu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The stable operation of a variable frequency pump is of great importance to the management of a water supply project. Analyzing the operation performance based on monitoring data is necessary for maintaining the stable operation of a variable frequency pump. Several sensors are installed at six monitoring points on the pump to collect signals including vibration velocity, vibration acceleration and vibration displacement. Monitoring signals are preprocessed by smoothing, adjusting waveform trend and filtering on the basis of Fast Fourier Transform (FFT). Then, the vibration features are extracted by power spectrum analysis and cepstrum analysis methods. According to the extracted features, the vibration law and actual operation performance of a variable frequency pump under different operating conditions are analyzed. Results indicate that the vibration amplitude of the pump varies sharply under the operating conditions of [15 Hz, 20 Hz] and [30 Hz, 35 Hz]. The operating condition of [0 Hz, 15 Hz] is the restricted operating area of the pump. The vibration and noise continue increasing under the operating conditions of [35 Hz, 50 Hz] and reach the maximum values at 50 Hz. Therefore, the optimal operating is within the range of [20 Hz, 30 Hz]. Finally, by analyzing the critical values of the operating conditions, the fault diagnosis and the evaluation of the operating status are conducted.

Förderung

  • Zhejiang Provincial Natural Science Foundation of China

Zitieren

APA

Hu, J., Wang, C., Shan, C., & Guo, Y. (2023). Monitoring and Analysis of the Operation Performance of Vertical Centrifugal Variable Frequency Pump in Water Supply System. Energies, 16(11), 4526. https://doi.org/10.3390/en16114526

Vancouver

Hu J, Wang C, Shan C, Guo Y. Monitoring and Analysis of the Operation Performance of Vertical Centrifugal Variable Frequency Pump in Water Supply System. Energies. 2023;16(11):4526. doi:10.3390/en16114526

BibTeX
@article{Hu2023,
  author = {Hu, Jianyong and Wang, Chaohao and Shan, Chengju and Guo, Yunhui},
  title = {Monitoring and Analysis of the Operation Performance of Vertical Centrifugal Variable Frequency Pump in Water Supply System},
  journal = {Energies},
  year = {2023},
  volume = {16},
  number = {11},
  pages = {4526},
  doi = {10.3390/en16114526}
}
Kostenlos starten →