In Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data

Andrea Alongi, Luca Sala, Adriana Angelotti, Livio Mazzarella

Energies · 22.05.2023 · 16 (10) · 4247

DOI: 10.3390/en16104247 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 22.05.2023. Verfasst von Andrea Alongi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Lombardy Region, Smart Living.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Energy retrofit of existing buildings is based on the assessment of the starting performance of the envelope. The procedure for the in situ measurement of thermal conductance is described in the ISO 9869-1:2014, which provides two techniques for data processing: the average method (AM) and the dynamic method (DM). This work studies their effectiveness using virtual data from numerical simulations based on a finite difference model applied to different wall kinds, considering winter and summer boundary conditions alternatively (Italian Milan-Linate TMY). The estimated thermal conductances are compared to the reference theoretical values. The main purposes are: (i) defining the shortest test duration that provides acceptable results; (ii) assess the reliability of the criteria provided by the standard to evaluate the measurement quality; (iii) evaluate the sensitivity of both methods to variables such as wall properties, boundary conditions and others more specific to the DM (namely, the number of time constants and linear equations). The AM always provides acceptable estimates in winter (−3.1% ÷ 10% error), with better outcomes when indoor heat flux is considered, except for the highly insulated wall, but is not effective in summer, despite the fulfillment of the acceptance criteria for the highly insulated wall. The DM provides improvements in both seasons (0.05% ÷ 8.6% absolute values of error), for most virtual samples, and requires shorter sampling periods, even below the 3 days limit suggested by the standard. The test on the confidence interval indicated by the ISO 9869-1:2014 is not reliable and measurements are sensitive to the number of linear equations, that is left to the user’s discretion without strict indications. This work suggests a possible approach for overcoming this issue, which requires deeper future investigation.

Förderung

  • Lombardy Region, Smart Living

Zitieren

APA

Alongi, A., Sala, L., Angelotti, A., & Mazzarella, L. (2023). In Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data. Energies, 16(10), 4247. https://doi.org/10.3390/en16104247

Vancouver

Alongi A, Sala L, Angelotti A, Mazzarella L. In Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data. Energies. 2023;16(10):4247. doi:10.3390/en16104247

BibTeX
@article{Alongi2023,
  author = {Alongi, Andrea and Sala, Luca and Angelotti, Adriana and Mazzarella, Livio},
  title = {In Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data},
  journal = {Energies},
  year = {2023},
  volume = {16},
  number = {10},
  pages = {4247},
  doi = {10.3390/en16104247}
}
Kostenlos starten →