Optimal Management of Battery and Fuel Cell-Based Decentralized Generation in DC Shipboard Microgrids
Energies · 08.02.2023 · 16 (4) · 1682
DOI: 10.3390/en16041682 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 08.02.2023. Verfasst von Massimiliano Luna und 5 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Economic Development (MISE).
Abstract (Originalsprache)
This paper proposes an energy management system (EMS) that aims at managing the modular direct current (DC) microgrids (MGs) of a hybrid DC/AC power system onboard cruise ships. Each shipboard microgrid is an electrically self-sufficient system supplied only by a fuel cell (FC) and a Lithium battery, and it powers the ship’s hotel services. However, continuously varying power demand profiles negatively affect the FC. Thus, the proposed EMS aims to minimize the FC operating point excursion on the source’s characteristic. This goal is pursued by exploiting the battery capability to manage load fluctuations and compensate for power demand forecasting errors. Furthermore, it is accomplished while satisfying all the operational constraints of the shipboard microgrids and ensuring daily battery charging/discharging cycles. The proposed EMS is based on two subsystems: (1) a rule-based microgrid supervisor, which makes the EMS capable of managing black start, normal operating conditions, and transient or faulty conditions; (2) an energy management (EM) algorithm, which allows achieving the desired goal without oversizing the battery, thus granting the cost-effectiveness of the solution and a reduced impact on technical volumes/weights on board. The EMS was tested with specific reference to a real-world case study, i.e., a 48,000 gross tonnage cruise ship under different operating scenarios, including black start and multi-day period operation of shipboard MGs. Test results showed that the operating points of the FC were always in the neighborhood of the point chosen by the MG designer, that the voltage variations were always well below 5%, guaranteeing stable operation, and that the black start operation was suitably handled by the EMS. According to the obtained results, the effectiveness of the proposed approach was assessed.
Förderung
- Italian Ministry of Economic Development (MISE)
Zitieren
APA
Luna, M., Tona, G. L., Accetta, A., Pucci, M., Pietra, A., & Piazza, M. C. D. (2023). Optimal Management of Battery and Fuel Cell-Based Decentralized Generation in DC Shipboard Microgrids. Energies, 16(4), 1682. https://doi.org/10.3390/en16041682
Vancouver
Luna M, Tona GL, Accetta A, Pucci M, Pietra A, Piazza MCD. Optimal Management of Battery and Fuel Cell-Based Decentralized Generation in DC Shipboard Microgrids. Energies. 2023;16(4):1682. doi:10.3390/en16041682
BibTeX
@article{Luna2023,
author = {Luna, Massimiliano and Tona, Giuseppe La and Accetta, Angelo and Pucci, Marcello and Pietra, Andrea and Piazza, Maria Carmela Di},
title = {Optimal Management of Battery and Fuel Cell-Based Decentralized Generation in DC Shipboard Microgrids},
journal = {Energies},
year = {2023},
volume = {16},
number = {4},
pages = {1682},
doi = {10.3390/en16041682}
}
EUVIMED