EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Impact of Transmission Line Modeling on Lightning Overvoltage

Jaimis Sajid Leon Colqui, Rodolfo Antônio Ribeiro de Moura, Marco Aurélio De Oliveira Schroeder, José Pissolato Filho, Sérgio Kurokawa

Energies · 27.01.2023 · 16 (3) · 1343

DOI: 10.3390/en16031343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 27.01.2023. Verfasst von Jaimis Sajid Leon Colqui und 4 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, the São Paulo Research Foundation (FAPESP).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In most of the work that investigates the backflashover phenomenon due to direct lightning strikes, using EMT-type simulators, transmission lines are represented by the J. Marti model and the ground effect is computed employing J. R. Carson’s formulations. Thus, the ground displacement current is neglected, the line voltage definition corresponds to the wire potential formulation, and soil resistivity is considered frequency-independent. These considerations can lead to erroneous measurements of the occurrences of the backflashover phenomenon in the insulator strings of transmission line. In this sense, this paper presents a systematic sensitivity analysis study of lightning overvoltage in insulator strings considering more physically consistent models of the transmission line, which consider the displacement current, ground admittance correction, rigorous voltage definition, and frequency-dependent soil parameters. According to the results, for the case study, transmission line parameters modeling can present a maximum percentual difference of around 71.54%, considering the frequency range of first strokes. This difference leads to a percent difference of around 5.25% in the maximum overvoltage across the insulator strings. These differences confirm that the occurrence or not of backflashover in the insulator strings, including the disruption time, are sensitive to the line model considered.

Förderung

  • the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • the São Paulo Research Foundation (FAPESP)

Zitieren

APA

Colqui, J. S. L., Moura, R. A. R. D., Schroeder, M. A. D. O., Filho, J. P., & Kurokawa, S. (2023). The Impact of Transmission Line Modeling on Lightning Overvoltage. Energies, 16(3), 1343. https://doi.org/10.3390/en16031343

Vancouver

Colqui JSL, Moura RARD, Schroeder MADO, Filho JP, Kurokawa S. The Impact of Transmission Line Modeling on Lightning Overvoltage. Energies. 2023;16(3):1343. doi:10.3390/en16031343

BibTeX
@article{Colqui2023,
  author = {Colqui, Jaimis Sajid Leon and Moura, Rodolfo Antônio Ribeiro de and Schroeder, Marco Aurélio De Oliveira and Filho, José Pissolato and Kurokawa, Sérgio},
  title = {The Impact of Transmission Line Modeling on Lightning Overvoltage},
  journal = {Energies},
  year = {2023},
  volume = {16},
  number = {3},
  pages = {1343},
  doi = {10.3390/en16031343}
}
Kostenlos starten →