EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Finite-Query Multi-View Unique-Count Calibration for Electronic Monitoring Systems

Chunfu Wei, Xinyan Liu

Electronics · 23.11.2026 · 15 (23) · 5464

DOI: 10.3390/electronics15235464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 23.11.2026. Verfasst von Chunfu Wei und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electronic monitoring systems require unique-person counts across camera views, where overlapping observations and unreliable appearance evidence complicate counting. We present DAWSON, a finite-query calibration framework that updates pairwise overlap estimates and the fused count using shared-person counts. Its expected union-error reduction (EER) policy selects queries by their expected reduction in a calibration residual and re-scores candidates after each response. A dustbin-based entropic optimal transport backend provides an alternative overlap proxy. In synthetic scenes and a static-camera WILDTRACK image-proxy bridge, the main query experiments use annotation-simulated responses. Under matched two-query protocols, EER yields lower mean absolute error (MAE) than Largest-overlap in all twelve degraded WILDTRACK settings across four frozen encoders. For complementary C4 + C5 + C7 coverage, EER reduces Clean MAE from 3.865 for the zero-query Max baseline to 2.960 using DINOv3 greedy proxies and a visible-union target; Max remains strongest among the four methods in the evaluated redundant and full-seven-view controls. In a separate offline pilot with one author and two development windows, five of 41 certain shared-count answers are exact. These findings show how finite-query calibration depends on camera coverage, proxy quality, and feedback reliability.

Zitieren

APA

Wei, C., & Liu, X. (2026). Finite-Query Multi-View Unique-Count Calibration for Electronic Monitoring Systems. Electronics, 15(23), 5464. https://doi.org/10.3390/electronics15235464

Vancouver

Wei C, Liu X. Finite-Query Multi-View Unique-Count Calibration for Electronic Monitoring Systems. Electronics. 2026;15(23):5464. doi:10.3390/electronics15235464

BibTeX
@article{Wei2026,
  author = {Wei, Chunfu and Liu, Xinyan},
  title = {Finite-Query Multi-View Unique-Count Calibration for Electronic Monitoring Systems},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {23},
  pages = {5464},
  doi = {10.3390/electronics15235464}
}
Kostenlos starten →