EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs

Khalil Alluhaybi, Mohammed A. Alharbi

Electronics · 23.11.2026 · 15 (23) · 5460

DOI: 10.3390/electronics15235460 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 23.11.2026. Verfasst von Khalil Alluhaybi und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Boundary-current-mode (BCM) operation can provide zero-voltage switching (ZVS) in single-phase photovoltaic microinverter stages without an auxiliary resonant circuit, but the current reversal required for commutation also changes current stress and switching-frequency behavior. This paper examines these tradeoffs in a 250 W full-bridge inverter. The charging and discharging of the MOSFET output capacitances are analyzed to establish the role of reverse inductor current in ZVS turn-on. Unipolar and bipolar modulation are compared in terms of switching-frequency variation and output-current distortion. Under a common maximum inductor-current excursion of 5 A, three current-boundary schemes, which are fixed reset current, fixed current variation, and variable reset current, are evaluated. For the conditions studied, fixed reset current produces the lowest RMS current and widest switching-frequency range, whereas fixed current variation gives the opposite trend; variable reset current lies between these limits. The experimental efficiency comparison favors fixed reset-current operation. Simulations and prototype measurements verify the commutation behavior and the current-boundary trajectories. The measured peak inverter efficiency is 98.5%, with a full-load grid-current THD of 1.67%. Relative to the 30 kHz hard-switched SPWM design, the BCM implementation exhibits an efficiency advantage of approximately 1.2–2.3 percentage points over the plotted 50–250 W output-power range, while reducing the reported inverter-side inductor-core volume from 26.46 to 11.98 cm3. These findings clarify the tradeoff between conduction-related losses and switching-frequency-dependent losses in the investigated BCM designs.

Zitieren

APA

Alluhaybi, K., & Alharbi, M. A. (2026). Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs. Electronics, 15(23), 5460. https://doi.org/10.3390/electronics15235460

Vancouver

Alluhaybi K, Alharbi MA. Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs. Electronics. 2026;15(23):5460. doi:10.3390/electronics15235460

BibTeX
@article{Alluhaybi2026,
  author = {Alluhaybi, Khalil and Alharbi, Mohammed A.},
  title = {Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {23},
  pages = {5460},
  doi = {10.3390/electronics15235460}
}
Kostenlos starten →