EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter

Sanghyeon Baeg, Myungsun Chun, Sung Hoon Chung, Jeonghwan Kim, Geunyong Bak, Sang Hoon Jeon

Electronics · 19.11.2026 · 15 (22) · 5391

DOI: 10.3390/electronics15225391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 19.11.2026. Verfasst von Sanghyeon Baeg und 5 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Education (MOE) and Gyeonggi Province, Republic of Korea.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work evaluates the accumulated dose at a High Bandwidth Memory (HBM)-relevant location during printed circuit board (PCB) X-ray inspection under real manufacturing conditions. Measurements used an Omron VT-X750 3D CT X-ray inspection system at 115 kV and 130 μA with 1 mm Al filtration. A silicon PIN diode dosimeter at selected HBM locations recorded the dose rate and accumulated dose during the inspection scan. HBM-relevant exposure was strongly affected by PCB attenuation, HBM/package attenuation, scan position, and backscatter. The 3 mm PCB reduced the dose rate by approximately one order of magnitude relative to the direct-beam reference, and the additional HBM attenuation corresponded to an effective Cu thickness of approximately 0.15–0.16 mm. After PCB transmission, most of the remaining exposure was attenuated in the HBM/package structure. Combining this estimate with the image-sensor-side backscatter gives an HBM-relevant exposure estimate of approximately 75% of the PCB-transmitted exposure (average dose-rate equivalent approximately 0.46 mGy(Si)/s), an operational value derived from detector-dose differences rather than a measured absorbed dose in the HBM dies. The dose-rate waveform showed that exposure at the HBM location accumulates through transient events as the beam scans the PCB. HBM exposure during PCB X-ray inspection cannot be estimated from machine settings or static geometry alone; PCB/package attenuation, scan trajectory, component location, and backscatter must be considered.

Förderung

  • National Research Foundation of Korea
  • Ministry of Education (MOE) and Gyeonggi Province, Republic of Korea

Zitieren

APA

Baeg, S., Chun, M., Chung, S. H., Kim, J., Bak, G., & Jeon, S. H. (2026). Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter. Electronics, 15(22), 5391. https://doi.org/10.3390/electronics15225391

Vancouver

Baeg S, Chun M, Chung SH, Kim J, Bak G, Jeon SH. Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter. Electronics. 2026;15(22):5391. doi:10.3390/electronics15225391

BibTeX
@article{Baeg2026,
  author = {Baeg, Sanghyeon and Chun, Myungsun and Chung, Sung Hoon and Kim, Jeonghwan and Bak, Geunyong and Jeon, Sang Hoon},
  title = {Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {5391},
  doi = {10.3390/electronics15225391}
}
Kostenlos starten →