EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind Farms

Jomana M. Helmi, Rizk M. Hamouda, Hadi M. Elhelw, Ahmed Abu-Siada

Electronics · 14.11.2026 · 15 (22) · 5306

DOI: 10.3390/electronics15225306 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 14.11.2026. Verfasst von Jomana M. Helmi und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Subsynchronous resonance (SSR) in doubly fed induction generator (DFIG)-based wind farms connected to series capacitor-compensated networks can be strongly influenced by the location of supplementary damping control. This paper proposes a mode-targeted eigenvalue sensitivity framework for identifying the most effective stabilizing signal injection location prior to controller tuning. In this regard, a unified dynamic model incorporating the drivetrain, DFIG, converter controls, DC link, and series compensated network is linearized for modal analysis. Participation factors identify the dominant states associated with the critical SSR mode and support the use of generator speed deviation as a suitable common feedback signal. The real part sensitivity of the critical eigenvalue to stabilizer gain is then evaluated for four candidate injection locations: the rotor-side converter (RSC) torque and reactive power control loops, and the grid-side converter (GSC) DC link and terminal voltage control loops. Among these locations, the RSC torque loop exhibits the strongest stabilizing sensitivity. Eigenvalue migration and time-domain simulations under identical operating and control conditions confirm the same ranking, while the SSR modal frequency remains essentially unchanged. The proposed approach provides a quantitative and physically interpretable means of determining the stabilizer location independently of controller tuning, offering a systematic strategy for SSR mitigation in converter-interfaced power systems.

Zitieren

APA

Helmi, J. M., Hamouda, R. M., Elhelw, H. M., & Abu-Siada, A. (2026). Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind Farms. Electronics, 15(22), 5306. https://doi.org/10.3390/electronics15225306

Vancouver

Helmi JM, Hamouda RM, Elhelw HM, Abu-Siada A. Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind Farms. Electronics. 2026;15(22):5306. doi:10.3390/electronics15225306

BibTeX
@article{Helmi2026,
  author = {Helmi, Jomana M. and Hamouda, Rizk M. and Elhelw, Hadi M. and Abu-Siada, Ahmed},
  title = {Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind Farms},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {5306},
  doi = {10.3390/electronics15225306}
}
Kostenlos starten →