Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused Research
Electronics · 03.11.2026 · 15 (21) · 5098
DOI: 10.3390/electronics15215098 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 03.11.2026. Verfasst von Suvish und 3 weiteren Autor:innen. Die Arbeit nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Sensor capability has outpaced the architectures available to integrate it: in near-body multimodal sensing, the binding constraint is no longer whether a variable can be measured, but whether a platform coordinates heterogeneous channels while preserving timing integrity, contextual interpretability, and extensibility. The gap is acute in ageing-focused research, which needs both side-specific comparison and heterogeneous sensing. We present the Deterministic Embedded Acquisition Platform Biosensing Hub (DeAP-BioHub), a dual-core STM32H755 architecture isolating acquisition from variable-latency subsystems by peripheral ownership. A real-time Cortex-M4 domain performs scheduled sensing, timestamping, and record creation, and a bare-metal Cortex-M7 domain carries telemetry, file-system logging, and operator interaction; the two share only a non-cacheable region and hardware semaphores, exchanging fixed 464-byte records with build-time offset assertions. With telemetry and logging active, the environmental channel held its nominal period at 1000.000 ms, at 1 ms timestamp resolution (SD 0.188 ms, n = 452), 96.5% exactly at nominal; the infrared channel’s 0.517% excess traced to that sensor’s own refresh cycle rather than the scheduler, and no storage-synchronization signature was detectable in the four sessions (combined Rayleigh test, p = 0.99). Contextual sensing shares that scheduling, record structure, and timestamp source rather than sitting in metadata: a fingertip registration was summarized descriptively by a first-order approach (τ = 154 s, R2 = 0.997), and a session reading flat on infrared alone stayed diagnosable from the environmental record. Ageing-focused research is the target application: this is laboratory verification of the acquisition substrate, not evaluation in older adults or clinical validation.
Zitieren
APA
Suvish, Balota, J. E., Sheela, P., & Sundaram, S. (2026). Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused Research. Electronics, 15(21), 5098. https://doi.org/10.3390/electronics15215098
Vancouver
Suvish, Balota JE, Sheela P, Sundaram S. Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused Research. Electronics. 2026;15(21):5098. doi:10.3390/electronics15215098
BibTeX
@article{Suvish2026,
author = {Suvish and Balota, Josiah E. and Sheela, Priyalakshmi and Sundaram, Senthilarasu},
title = {Deterministic Edge Acquisition of Contextual, Multimodal Physiological Signals: A Bilateral-Ready Dual-Core IoT Biosensing Architecture for Ageing-Focused Research},
journal = {Electronics},
year = {2026},
volume = {15},
number = {21},
pages = {5098},
doi = {10.3390/electronics15215098}
}