Coordinated Sizing of Transformer and Hybrid Energy Storage Systems for PV-Integrated Ultra-Fast EV Charging Stations Considering Battery Degradation
Electronics · 02.11.2026 · 15 (21) · 5075
DOI: 10.3390/electronics15215075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 02.11.2026. Verfasst von Hao Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Anhui Electric Power Co., Ltd., Hefei Power Supply Company, Hefei University of Technology.
Abstract (Originalsprache)
Ultra-fast charging stations can impose substantial short-term power fluctuations and high transformer capacity requirements on distribution networks. To address the coupled planning and operational challenges of such stations, this study proposes a planning-operation coordinated sizing framework for a photovoltaic-integrated ultra-fast charging station. Unlike many existing approaches that address transformer sizing, energy storage configuration, and battery degradation separately or only partially couple them, the proposed framework jointly determines transformer capacity, battery capacity, and supercapacitor capacity while incorporating battery cycling degradation into the long-term storage cost evaluation. Representative charging scenarios are extracted from historical charging-load data and used for capacity planning. At the planning level, the average daily comprehensive cost is minimized by coordinating transformer investment, hybrid energy storage investment, operating cost, and degradation-dependent battery lifetime. At the operation level, battery and supercapacitor dispatch is optimized considering both operating economy and grid-connected power fluctuation. The upper-level sizing problem is solved using quantum-behaved particle swarm optimization. Sobol-sequence initialization and a nonlinear contraction-expansion coefficient are adopted in the implementation to enhance the distribution of the initial population and adjust the search range during the iterative process. The lower-level mixed-integer linear programming problem is solved using Gurobi. In the studied commercial-area case, the proposed hybrid energy storage configuration reduces the transformer capacity from 326 kVA to 201 kVA. Compared with the no-storage scheme, total costs are reduced by 14.9% and 14.3%, while the absolute deviations of grid-connected power are reduced by 93.4% and 94.8% for the two representative days. Compared with battery-only storage, daily battery cycle counts are further reduced by 60.5% and 65.2%. The results demonstrate that the proposed coordinated sizing framework can simultaneously reduce infrastructure capacity requirements and operating costs, improve grid integration performance, and alleviate battery cycling degradation in PV-integrated ultra-fast charging stations.
Förderung
- State Grid Anhui Electric Power Co., Ltd., Hefei Power Supply Company
- Hefei University of Technology
Zitieren
APA
Zhang, H., Wang, H., Chen, L., Zhang, Y., Liu, Y., & Shi, Y. (2026). Coordinated Sizing of Transformer and Hybrid Energy Storage Systems for PV-Integrated Ultra-Fast EV Charging Stations Considering Battery Degradation. Electronics, 15(21), 5075. https://doi.org/10.3390/electronics15215075
Vancouver
Zhang H, Wang H, Chen L, Zhang Y, Liu Y, Shi Y. Coordinated Sizing of Transformer and Hybrid Energy Storage Systems for PV-Integrated Ultra-Fast EV Charging Stations Considering Battery Degradation. Electronics. 2026;15(21):5075. doi:10.3390/electronics15215075
BibTeX
@article{Zhang2026,
author = {Zhang, Hao and Wang, Haiwei and Chen, Lu and Zhang, Yang and Liu, Yu and Shi, Yong},
title = {Coordinated Sizing of Transformer and Hybrid Energy Storage Systems for PV-Integrated Ultra-Fast EV Charging Stations Considering Battery Degradation},
journal = {Electronics},
year = {2026},
volume = {15},
number = {21},
pages = {5075},
doi = {10.3390/electronics15215075}
}
EUVIMED