EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Construction Method for a Domain-Specific LLM for Substation Safety Hazard Diagnosis Based on a Bilateral Dual-Branch Dual-LoRA Architecture

Yan Liu, Xingyu Wang, Haonan Du, Jinhua Yu

Electronics · 01.11.2026 · 15 (21) · 5065

DOI: 10.3390/electronics15215065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 01.11.2026. Verfasst von Yan Liu und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Basic Research Program of Shaanxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Substation safety inspection requires models that recognize visual hazards and organize image-linked diagnostic text. This paper specifies a bilateral Dual-LoRA adaptation framework for Qwen2.5-VL-7B-Instruct, with the pretrained backbone and native patch merger frozen, and reevaluates two archived adapter-output runs. The authors report a collection of 1173 records across five hazard categories. The two output archives contain the same 121 image identifiers and reference labels. A deterministic parser assigns categories from the risk-type field, enabling full confusion matrices and per-class precision, recall, and F1. Archived Run A correctly classifies 115 images (95.04%; Macro-F1 0.9282) and Run B 116 (95.87%; Macro-F1 0.9358). The one-image difference is not significant under the exact paired McNemar test (p = 1.000). Dangling-object recall is 7/10 for both runs. Reproducible text-overlap and structural-field audits characterize the stored diagnostic responses. Analytical inventories compare adapter placement and rank separately from measured outputs. The evaluation is limited to an internal cohort; overfitting risk remains, and unseen-site generalization and independent field effectiveness have not been established. The bilateral specification and proposed inspection workflow are distinguished from what the retained checkpoints and output records independently verify.

Förderung

  • Natural Science Basic Research Program of Shaanxi Province

Zitieren

APA

Liu, Y., Wang, X., Du, H., & Yu, J. (2026). Construction Method for a Domain-Specific LLM for Substation Safety Hazard Diagnosis Based on a Bilateral Dual-Branch Dual-LoRA Architecture. Electronics, 15(21), 5065. https://doi.org/10.3390/electronics15215065

Vancouver

Liu Y, Wang X, Du H, Yu J. Construction Method for a Domain-Specific LLM for Substation Safety Hazard Diagnosis Based on a Bilateral Dual-Branch Dual-LoRA Architecture. Electronics. 2026;15(21):5065. doi:10.3390/electronics15215065

BibTeX
@article{Liu2026,
  author = {Liu, Yan and Wang, Xingyu and Du, Haonan and Yu, Jinhua},
  title = {Construction Method for a Domain-Specific LLM for Substation Safety Hazard Diagnosis Based on a Bilateral Dual-Branch Dual-LoRA Architecture},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {21},
  pages = {5065},
  doi = {10.3390/electronics15215065}
}
Kostenlos starten →