Optimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm
Electronics · 21.08.2026 · 15 (16) · 3744
DOI: 10.3390/electronics15163744 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 21.08.2026. Verfasst von Yiqun Kang und 4 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and technology projects of the State Grid Hubei Corporation.
Abstract (Originalsprache)
High penetration levels of renewable energy and power electronic apparatus create prominent obstacles for novel power grids, which mainly manifested as inadequate system inertia and a deteriorated stability margin. To overcome such drawbacks, this research develops an operational control method to maintain safe and steady grid operation with large-capacity grid-forming energy storage connected to the system. This paper first builds a dynamic voltage model covering grid-forming energy storage, distributed renewable generators, and distribution network frameworks. Then it explores how different control parameter settings of grid-forming storage affect dynamic voltage regulation capabilities under distinct R-L ratio scenarios. Since the correlation between energy storage control variables and voltage regulation features is highly nonlinear and complicated, trajectory sensitivity analysis is adopted to linearize these coupling constraints, which are further embedded into the power system security operation mathematical model. A chaotic particle swarm optimization (PSO) algorithm is used to solve the constructed optimization model. Simulation tests on a modified IEEE 33-bus test system ultimately prove that the proposed method is reliable and practically applicable. Simulation results on the modified IEEE 33-bus test system demonstrate that the proposed strategy restricts grid voltage fluctuation rate to only 2.41%, raises renewable energy accommodation rate up to 98.4%, and achieves a 30.6% reduction in overall system operation cost compared to traditional energy storage configuration schemes, which fully verifies the outstanding effectiveness and practical engineering feasibility of the proposed method.
Förderung
- Science and technology projects of the State Grid Hubei Corporation
Zitieren
APA
Kang, Y., Huang, H., Feng, B., Hu, Y., & Wang, Q. (2026). Optimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm. Electronics, 15(16), 3744. https://doi.org/10.3390/electronics15163744
Vancouver
Kang Y, Huang H, Feng B, Hu Y, Wang Q. Optimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm. Electronics. 2026;15(16):3744. doi:10.3390/electronics15163744
BibTeX
@article{Kang2026,
author = {Kang, Yiqun and Huang, Huizhen and Feng, Bingyang and Hu, Yuxuan and Wang, Qiujie},
title = {Optimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm},
journal = {Electronics},
year = {2026},
volume = {15},
number = {16},
pages = {3744},
doi = {10.3390/electronics15163744}
}
EUVIMED