Single-Phase Ground Fault Line Selection of Wind Farm Collector Line Based on Transient Zero-Mode Current

Huida Duan, Song Bai, Zhipeng Gao, Shihao Zhao, Yihan Wang, Ying Zhao

Electronics · 24.07.2026 · 15 (15) · 3264

DOI: 10.3390/electronics15153264 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 24.07.2026. Verfasst von Huida Duan und 5 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Department Project of Jilin Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Faults in wind farm multi-branch collector lines produce weak transient zero-mode current characteristics, rendering conventional amplitude- and phase-based selection methods ineffective. To address this, the paper proposes a faulty feeder selection method that integrates transient zero-mode differential current with the S-transform. A π-type zero-mode network is first established to reveal the composition and variation in transient zero-mode current under different operating conditions. Theoretical analysis demonstrates a distinguishable feature—the sending-end current of the faulted branch exhibits significantly larger amplitude and opposite polarity compared with non-faulted branches—while the end-side currents near wind turbines remain highly similar and thus hinder accurate selection. Motivated by this disparity, the adaptive time–frequency focusing property of the S-transform is exploited to extract high-frequency energy and differential signatures within the optimal band, from which a dual criterion consisting of the differential feature quantity Dm and the time–frequency energy Em is constructed. The method is validated on a 35 kV DFIG-based wind farm collector line model built in PSCAD/EMTDC and benchmarked against the wavelet transform and empirical mode decomposition under various operating conditions. The results confirm that the proposed method accurately distinguishes bus faults from branch faults, reliably identifies the faulty feeder, and remains unaffected by fault distance and operating conditions, demonstrating strong robustness and anti-interference capability.

Förderung

  • Science and Technology Department Project of Jilin Province

Zitieren

APA

Duan, H., Bai, S., Gao, Z., Zhao, S., Wang, Y., & Zhao, Y. (2026). Single-Phase Ground Fault Line Selection of Wind Farm Collector Line Based on Transient Zero-Mode Current. Electronics, 15(15), 3264. https://doi.org/10.3390/electronics15153264

Vancouver

Duan H, Bai S, Gao Z, Zhao S, Wang Y, Zhao Y. Single-Phase Ground Fault Line Selection of Wind Farm Collector Line Based on Transient Zero-Mode Current. Electronics. 2026;15(15):3264. doi:10.3390/electronics15153264

BibTeX
@article{Duan2026,
  author = {Duan, Huida and Bai, Song and Gao, Zhipeng and Zhao, Shihao and Wang, Yihan and Zhao, Ying},
  title = {Single-Phase Ground Fault Line Selection of Wind Farm Collector Line Based on Transient Zero-Mode Current},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {15},
  pages = {3264},
  doi = {10.3390/electronics15153264}
}
Kostenlos starten →