EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Invasive Supply Voltage Unbalance Detection and Monitoring in AC/DC/AC Converters Using DC-Link Current Analysis

Stanisław Oliszewski, Mateusz Dybkowski

Electronics · 21.07.2026 · 15 (14) · 3208

DOI: 10.3390/electronics15143208 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 21.07.2026. Verfasst von Stanisław Oliszewski und 1 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a single-sensor solution for the detection and monitoring of power supply voltage unbalances in AC/DC/AC converters. By analyzing the DC-link input current, it is demonstrated that characteristic current pulse deformations directly indicate the presence and severity of grid voltage imbalances. Based on these pulse profile variations, a novel diagnostic metric termed the Current Ripple Voltage Unbalance Factor (CRVUF) is derived. The proposed methodology was comprehensively evaluated and validated through both simulation studies and experimental testing. The presented approach offers a computationally efficient, non-invasive alternative to conventional monitoring systems, effectively reducing the number of required voltage sensors from three to a single current sensor.

Zitieren

APA

Oliszewski, S., & Dybkowski, M. (2026). Non-Invasive Supply Voltage Unbalance Detection and Monitoring in AC/DC/AC Converters Using DC-Link Current Analysis. Electronics, 15(14), 3208. https://doi.org/10.3390/electronics15143208

Vancouver

Oliszewski S, Dybkowski M. Non-Invasive Supply Voltage Unbalance Detection and Monitoring in AC/DC/AC Converters Using DC-Link Current Analysis. Electronics. 2026;15(14):3208. doi:10.3390/electronics15143208

BibTeX
@article{Oliszewski2026,
  author = {Oliszewski, Stanisław and Dybkowski, Mateusz},
  title = {Non-Invasive Supply Voltage Unbalance Detection and Monitoring in AC/DC/AC Converters Using DC-Link Current Analysis},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {14},
  pages = {3208},
  doi = {10.3390/electronics15143208}
}
Kostenlos starten →