EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Calibration of Roughness of Standard Samples Using Point Cloud Based on Line Chromatic Confocal Method

Haotian Guo, Ting Chen, Xinke Xu, Yuexin Qiu, Jian Wu, Lei Wang, Huaichu Ye, Xuwen Chen, Ning Chen

Electronics · 04.04.2026 · 15 (7) · 1517

DOI: 10.3390/electronics15071517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 04.04.2026. Verfasst von Haotian Guo und 8 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Market Supervision and Administration Bureau, Zhejiang Provincial Natural Science Foundation, State Administration for Market Regulation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article proposes a calibration method combining line chromatic confocal and 3D point cloud processing to solve surface damage and low efficiency in traditional roughness sample calibration. Line chromatic confocal sensors scan roughness samples to obtain dense point clouds. We propose a back projection mechanism, the adaptive density-based spatial clustering of applications with noise statistical outlier removal (BPM-ADBSCAN-SOR) algorithm that utilizes the ADBSCAN and SOR algorithms to address outlier noise and near-field noise in low-resolution point clouds, respectively, and then employs bounding boxes to crop the original high-resolution point cloud, thereby achieving multi-scale noise removal and point cloud clustering. We propose a Steady-State Confidence-Weighted Robust Gaussian Filtering (SSCW-RGF) algorithm, which calculates the range of the steady-state region, designs a steady-state region credibility weighting function to apply a weighted correction to the baseline fitting results, and then incorporates M-estimation theory to develop a robust Gaussian filtering algorithm weighted by steady-state region credibility, thereby mitigating the impact of outliers on Gaussian baseline fitting. Experiments verify the system accuracy: repeatability standard deviation is 0.0355 μm, relative repeatability error 0.3984%. Compared with sample block nominal values, the maximum absolute error is −0.745 μm, meeting specification tolerance. Compared with the contact profilometer, the maximum absolute error is 0.050 μm, the maximum relative error is +4.5%, and the calibration efficiency is improved by 90%. It provides a new approach for surface roughness calibration

Förderung

  • Zhejiang Provincial Market Supervision and Administration Bureau
  • Zhejiang Provincial Natural Science Foundation
  • State Administration for Market Regulation

Zitieren

APA

Guo, H., Chen, T., Xu, X., Qiu, Y., Wu, J., Wang, L., Ye, H., Chen, X., & Chen, N. (2026). Calibration of Roughness of Standard Samples Using Point Cloud Based on Line Chromatic Confocal Method. Electronics, 15(7), 1517. https://doi.org/10.3390/electronics15071517

Vancouver

Guo H, Chen T, Xu X, Qiu Y, Wu J, Wang L, et al. Calibration of Roughness of Standard Samples Using Point Cloud Based on Line Chromatic Confocal Method. Electronics. 2026;15(7):1517. doi:10.3390/electronics15071517

BibTeX
@article{Guo2026,
  author = {Guo, Haotian and Chen, Ting and Xu, Xinke and Qiu, Yuexin and Wu, Jian and Wang, Lei and Ye, Huaichu and Chen, Xuwen and Chen, Ning},
  title = {Calibration of Roughness of Standard Samples Using Point Cloud Based on Line Chromatic Confocal Method},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {7},
  pages = {1517},
  doi = {10.3390/electronics15071517}
}
Kostenlos starten →