EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Joint Denoising and Motion-Correction for Low-Dose CT Myocardial Perfusion Imaging Using Deep Learning

Mahmud Hasan, Aaron So, Mahmoud R. El-Sakka

Electronics · 19.03.2026 · 15 (6) · 1286

DOI: 10.3390/electronics15061286 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 19.03.2026. Verfasst von Mahmud Hasan und 2 weiteren Autor:innen. Die Arbeit nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Computed Tomography (CT) is a widely used imaging modality that employs X-rays and computational reconstruction to visualize internal anatomy. Although higher radiation doses produce higher-quality images, they also increase long-term cancer risk, motivating the use of low-dose protocols. However, low-dose CT data inherently suffer from elevated Poisson–Gaussian noise, necessitating effective denoising strategies. In myocardial CT perfusion (CTP) imaging, this challenge is compounded by residual cardiac motion, which misaligns consecutive time points and impairs accurate estimation of perfusion maps for diagnosing coronary artery disease. Traditional approaches typically treat these two problems, noise and motion, separately, denoising the reconstructed images first or applying the registration first. Such serial pipelines often degrade clinically significant features; e.g., denoising may destroy structural details essential for registration, while motion correction can distort subtle intensity cues needed for noise modelling. To overcome these limitations, we propose a unified deep learning framework that performs noise suppression and motion correction jointly for low-dose myocardial CTP. The method integrates two complementary components through a parallel ensemble strategy: (i) a modified Fast and Flexible Denoising Network (FFDNet) that incorporates noise-level maps to mitigate blended noise effectively, and (ii) a CNN-based registration model, extended with Time Enhancement Curve (TEC) correction and 4D physiological consistency constraints to estimate temporally coherent and anatomically plausible motion fields. By combining their outputs without iterative dependencies, the proposed framework produces motion-corrected and denoised CTP sequences in a single unified processing step, thereby better preserving myocardial structure and perfusion dynamics than conventional serial pipelines. The model has been evaluated using both reference-based (MSE, PSNR, SSIM, PCC, Noise Variance, TRE) and no-reference (NIQE, FID, KID, AUC) image quality metrics, supplemented by expert human assessment. Results demonstrate that jointly learning noise characteristics and motion patterns enables restoration of low-dose CTP images while minimizing feature corruption, thereby advancing the clinical utility of low-dose myocardial CTP imaging.

Zitieren

APA

Hasan, M., So, A., & El-Sakka, M. R. (2026). Joint Denoising and Motion-Correction for Low-Dose CT Myocardial Perfusion Imaging Using Deep Learning. Electronics, 15(6), 1286. https://doi.org/10.3390/electronics15061286

Vancouver

Hasan M, So A, El-Sakka MR. Joint Denoising and Motion-Correction for Low-Dose CT Myocardial Perfusion Imaging Using Deep Learning. Electronics. 2026;15(6):1286. doi:10.3390/electronics15061286

BibTeX
@article{Hasan2026,
  author = {Hasan, Mahmud and So, Aaron and El-Sakka, Mahmoud R.},
  title = {Joint Denoising and Motion-Correction for Low-Dose CT Myocardial Perfusion Imaging Using Deep Learning},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {1286},
  doi = {10.3390/electronics15061286}
}
Kostenlos starten →