Comparative Evaluation of Deep Learning Models for Respiratory Rate Estimation Using PPG-Derived Numerical Features
Electronics · 07.03.2026 · 15 (5) · 1108
DOI: 10.3390/electronics15051108 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 07.03.2026. Verfasst von Syed Mahedi Hasan und 2 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Respiratory rate (RR) is a critical vital sign for the early detection of hypoxia and respiratory deterioration, yet its continuous monitoring remains challenging in clinical environments. Photoplethysmography (PPG) provides a non-invasive source of physiological information from which respiratory dynamics can be inferred. In this study, numerical physiological features derived from PPG data were used to comparatively evaluate multiple deep learning models for respiratory rate estimation. Fixed-length sliding windows were constructed from the dataset and used to train five neural network architectures: a Deep Feedforward Neural Network (DFNN), unidirectional and bidirectional Recurrent Neural Networks (RNN, Bi-RNN), and unidirectional and bidirectional Long Short-Term Memory networks (LSTM, Bi-LSTM). Model performance was assessed using mean absolute error (MAE), root mean squared error (RMSE), coefficient of determination (R2), and computational runtime. Results indicate that models incorporating temporal dependencies outperform the static feedforward baseline, achieving MAE values as low as 0.521 breaths/min, making them competitive with or lower than previously reported PPG-based approaches. These findings highlight the effectiveness of temporal deep learning models for respiratory rate estimation from PPG-derived numerical features and provide insight into accuracy–efficiency trade-offs relevant to real-time monitoring applications.
Zitieren
APA
Hasan, S. M., Raj, M. G. S., & Mitra, K. (2026). Comparative Evaluation of Deep Learning Models for Respiratory Rate Estimation Using PPG-Derived Numerical Features. Electronics, 15(5), 1108. https://doi.org/10.3390/electronics15051108
Vancouver
Hasan SM, Raj MGS, Mitra K. Comparative Evaluation of Deep Learning Models for Respiratory Rate Estimation Using PPG-Derived Numerical Features. Electronics. 2026;15(5):1108. doi:10.3390/electronics15051108
BibTeX
@article{Hasan2026,
author = {Hasan, Syed Mahedi and Raj, Mercy Golda Sam and Mitra, Kunal},
title = {Comparative Evaluation of Deep Learning Models for Respiratory Rate Estimation Using PPG-Derived Numerical Features},
journal = {Electronics},
year = {2026},
volume = {15},
number = {5},
pages = {1108},
doi = {10.3390/electronics15051108}
}