EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Symbol Synchronization for Optical Intrabody Nanocommunication Using Noncoherent Detection

Pankaj Singh, Sung-Yoon Jung

Electronics · 04.09.2025 · 14 (17) · 3537

DOI: 10.3390/electronics14173537 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 04.09.2025. Verfasst von Pankaj Singh und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gyeongsangbuk-do RISE (Regional Innovation System & Education) project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical intrabody wireless nanosensor networks (OiWNSNs) enable groundbreaking biomedical applications via optical nanocommunication within biological tissues. Synchronization is critical for accurate data recovery in these energy- and size-constrained nanonetworks. In this study, we investigate timing synchronization in a highly dispersive and noisy intravascular optical channel, particularly under an on–off keying preamble comprising Gaussian optical pulses. We proposed a synchronization scheme based on the repetitive transmission of a preamble and noncoherent detection using continuous-time moving average filters with multiple integrator windows. The simulation results reveal that increasing the communication distance degrades the synchronization performance. To counter this degradation, we can increase the number of preamble repetitions, which markedly improves the system reliability and timing accuracy due to the averaging gain, although the performance saturates due to the dispersion floor inherent in the blood channel. Moreover, we found that low-resolution nanoreceivers with fewer integrators outperform high-resolution designs in dispersive environments, as they mitigate the energy-splitting problem due to pulse broadening. This tradeoff between temporal resolution and robustness highlights the importance of channel-aware receiver design. Overall, this study provides key insights into the physical layer design of OiWNSNs and offers practical guidelines for achieving robust synchronization under realistic biological conditions.

Förderung

  • Gyeongsangbuk-do RISE (Regional Innovation System & Education) project

Zitieren

APA

Singh, P., & Jung, S. (2025). Symbol Synchronization for Optical Intrabody Nanocommunication Using Noncoherent Detection. Electronics, 14(17), 3537. https://doi.org/10.3390/electronics14173537

Vancouver

Singh P, Jung S. Symbol Synchronization for Optical Intrabody Nanocommunication Using Noncoherent Detection. Electronics. 2025;14(17):3537. doi:10.3390/electronics14173537

BibTeX
@article{Singh2025,
  author = {Singh, Pankaj and Jung, Sung-Yoon},
  title = {Symbol Synchronization for Optical Intrabody Nanocommunication Using Noncoherent Detection},
  journal = {Electronics},
  year = {2025},
  volume = {14},
  number = {17},
  pages = {3537},
  doi = {10.3390/electronics14173537}
}
Kostenlos starten →