EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved Droop Control Strategy for Islanded Microgrids Based on the Adaptive Weight Particle Swarm Optimization Algorithm

Binge Tu, Xianglian Xu, Yifeng Gu, Kaitian Deng, Yuli Xu, Tianyu Zhang, Xinrong Gao, Kangning Wang, Qingjie Wei

Electronics · 24.02.2025 · 14 (5) · 893

DOI: 10.3390/electronics14050893 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 24.02.2025. Verfasst von Binge Tu und 8 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In islanded low-voltage microgrids, the parallel operation of inverters using traditional droop control strategies often results in imbalanced output impedances among inverters due to variations in line impedance. This imbalance prevents the equitable distribution of reactive power according to the designated droop coefficients. To address this challenge, this paper proposes an improved droop control strategy. First, the virtual impedance control method is added to the strategy of traditional droop control, and then an adaptive weight particle swarm optimization algorithm (APSO) is introduced in the voltage outer loop control module to optimize the parameter setting of the PID controller. Finally, a comparative analysis was conducted on the output results of the improved droop control before and after introducing the algorithm. This proposed strategy is systematically analyzed through modeling and simulation in the MATLAB/Simulink environment to assess its impact on output voltage stability, reactive power sharing, and circulating current magnitude among parallel inverters. The simulation results indicate that the improved droop control with the introduction of virtual impedance effectively achieves equal reactive power sharing among parallel inverters. Moreover, by employing the APSO algorithm, the stability of the inverter output voltage is significantly enhanced. The maximum voltage deviation between two inverters is reduced to below 0.03%, while the maximum reactive power deviation decreases from over 3.5% to less than 2.5%. These improvements effectively reduce the circulating currents between two paralleled inverters, ensuring that the maximum current remains below 1.5 A and the minimum stays above −1 A.

Zitieren

APA

Tu, B., Xu, X., Gu, Y., Deng, K., Xu, Y., Zhang, T., Gao, X., Wang, K., & Wei, Q. (2025). Improved Droop Control Strategy for Islanded Microgrids Based on the Adaptive Weight Particle Swarm Optimization Algorithm. Electronics, 14(5), 893. https://doi.org/10.3390/electronics14050893

Vancouver

Tu B, Xu X, Gu Y, Deng K, Xu Y, Zhang T, et al. Improved Droop Control Strategy for Islanded Microgrids Based on the Adaptive Weight Particle Swarm Optimization Algorithm. Electronics. 2025;14(5):893. doi:10.3390/electronics14050893

BibTeX
@article{Tu2025,
  author = {Tu, Binge and Xu, Xianglian and Gu, Yifeng and Deng, Kaitian and Xu, Yuli and Zhang, Tianyu and Gao, Xinrong and Wang, Kangning and Wei, Qingjie},
  title = {Improved Droop Control Strategy for Islanded Microgrids Based on the Adaptive Weight Particle Swarm Optimization Algorithm},
  journal = {Electronics},
  year = {2025},
  volume = {14},
  number = {5},
  pages = {893},
  doi = {10.3390/electronics14050893}
}