Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms

Yong Sun, Hongbin Wu, Xiaozhe Song, Haifeng Zhang, Yifu Zhang, Jikai Chen, Hongpeng Liu

Electronics · 30.09.2024 · 13 (19) · 3879

DOI: 10.3390/electronics13193879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 30.09.2024. Verfasst von Yong Sun und 6 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In Doubly Fed Induction Generator (DFIG)-based wind farms with Static Var Generators (SVGs), high-frequency resonance will be more like to occur when an unloaded cable is put into operation, which will threaten the stable operation of the wind farm. To address this issue, the influence of power outer loops on the impedance of grid-connected inverters is considered. Based on harmonic linearization, theoretical models for the sequence impedances of DFIGs, Grid-following (GFL) SVGs, and Grid-forming (GFM) SVGs are established. The correctness of the three models is verified by impedance scanning using the frequency sweep method. Through a comparative analysis of these sequence impedances, it is found that unlike the GFM SVG (which exhibits inductive impedance), the GFL SVG exhibits capacitive impedance in the high-frequency band, which leads to negative damping characteristics in the high-frequency band for the wind farm system with the grid-following SVG; thereby, the risk of high-frequency resonance also increases accordingly. On the contrary, GFM control adopted by SVGs can effectively eliminate the negative damping region in the high-frequency band for wind farms to suppress high-frequency resonance. Meanwhile, for grid-forming SVGs, the parameter variations in power synchronous loops have no significant impact on the suppressing effect of high-frequency resonance for wind farms. Finally, an electromagnetic simulation model for a DFIG-based wind farm system with an SVG is established using the StarSim-HIL (hardware-in-the-loop) experiment platform, and the simulation results validate the correctness of the theoretical analysis.

Förderung

  • State Grid Corporation of China

Zitieren

APA

Sun, Y., Wu, H., Song, X., Zhang, H., Zhang, Y., Chen, J., & Liu, H. (2024). Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms. Electronics, 13(19), 3879. https://doi.org/10.3390/electronics13193879

Vancouver

Sun Y, Wu H, Song X, Zhang H, Zhang Y, Chen J, et al. Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms. Electronics. 2024;13(19):3879. doi:10.3390/electronics13193879

BibTeX
@article{Sun2024,
  author = {Sun, Yong and Wu, Hongbin and Song, Xiaozhe and Zhang, Haifeng and Zhang, Yifu and Chen, Jikai and Liu, Hongpeng},
  title = {Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms},
  journal = {Electronics},
  year = {2024},
  volume = {13},
  number = {19},
  pages = {3879},
  doi = {10.3390/electronics13193879}
}
Kostenlos starten →