EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Heart Sound Signals Classification with Image Conversion Employed

Erqiang Deng, Yibei Jia, Guobin Zhu, Erqiang Zhou

Electronics · 22.03.2024 · 13 (7) · 1179

DOI: 10.3390/electronics13071179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 22.03.2024. Verfasst von Erqiang Deng und 3 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Sichuan Science and Technology Innovation Platform and Talent Plan, Sichuan Science and Technology Support Plan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The number of patients with cardiovascular diseases worldwide is increasing rapidly, while medical resources are increasingly scarce. Heart sound classification, as the most direct means of discovering cardiovascular diseases, is attracting the attention of researchers around the world. Although great progress has been made in heart sound classification in recent years, most of them are based on traditional statistical feature methods and temporal dimension features. These traditional temporal dimension feature representation and classification methods cannot achieve good classification accuracy. This paper proposes a new partition attention module and Fusionghost module, and the entire network framework is named PANet. Without segmentation of the heart sound signal, the heart sound signal is converted into a bispectrum and input into the proposed framework for feature extraction and classification tasks. The network makes full use of multi-scale feature extraction and feature map fusion, improving the network feature extraction ability. This paper conducts a comprehensive study of the performance of different network parameters and different module numbers, and compares the performance with the most advanced algorithms currently available. Experiments have shown that for two classification problems (normal or abnormal), the classification accuracy rate on the 2016 PhysioNet/CinC Challenge database reached 97.89%, the sensitivity was 96.96%, and the specificity was 98.85%.

Förderung

  • National Natural Science Foundation of China
  • Sichuan Science and Technology Innovation Platform and Talent Plan
  • Sichuan Science and Technology Support Plan

Zitieren

APA

Deng, E., Jia, Y., Zhu, G., & Zhou, E. (2024). Heart Sound Signals Classification with Image Conversion Employed. Electronics, 13(7), 1179. https://doi.org/10.3390/electronics13071179

Vancouver

Deng E, Jia Y, Zhu G, Zhou E. Heart Sound Signals Classification with Image Conversion Employed. Electronics. 2024;13(7):1179. doi:10.3390/electronics13071179

BibTeX
@article{Deng2024,
  author = {Deng, Erqiang and Jia, Yibei and Zhu, Guobin and Zhou, Erqiang},
  title = {Heart Sound Signals Classification with Image Conversion Employed},
  journal = {Electronics},
  year = {2024},
  volume = {13},
  number = {7},
  pages = {1179},
  doi = {10.3390/electronics13071179}
}
Kostenlos starten →