EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Adaptive Control Method and Learning Strategy for Ultrasound-Guided Puncture Robot

Tao Li, Quan Zeng, Jinbiao Li, Cheng Qian, Hanmei Yu, Jian Lu, Yi Zhang, Shoujun Zhou

Electronics · 31.01.2024 · 13 (3) · 580

DOI: 10.3390/electronics13030580 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 31.01.2024. Verfasst von Tao Li und 7 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Project of China, National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of a new generation of minimally invasive surgery is mainly reflected in robot-assisted diagnosis and treatment methods and their clinical applications. It is a clinical concern for robot-assisted surgery to use a multi-joint robotic arm performing human ultrasound scanning or ultrasound-guided percutaneous puncture. Among them, the motion control of the robotic arm, and the guiding and contact scanning processes of the ultrasonic (US-) probe determine the diagnosis effect, as well as the accuracy and safety of puncture surgery. To address these challenges, this study developed an intelligent robot-assisted system integrating autonomous US inspection and needle positioning, which has relation to several intelligent algorithms such as adaptive flexible control of the robot arm, autonomous US-scanning, and real-time attitude adjustment of the puncture needle. To improve the cooperativity of the spatial operation of the robot end-effector, we propose an adaptive flexible control algorithm that allows the operator to control the robot arm flexibly with low damping. To achieve the stability and uniformity of contact detection and imaging, we introduced a self-scanning method of US-probe based on reinforcement learning and built a software model of variable stiffness based on MuJoco to verify the constant force and velocity required by the end mechanism. We conducted a fixed trajectory scanning experiment at a scanning speed of 0.06 m/s. The force curve generally converges towards the desired contact force of 10 N, with minor oscillations around this value. For surgical process monitoring, we adopted the puncture needle detection algorithm based on Unet++ to acquire the position and attitude information of the puncture needle in real time. In short, we proposed and verified an adaptive control method and learning strategy by using an UR robotic arm equipped with a US-probe and puncture needle, and we improved the intelligence of the US-guided puncture robot.

Förderung

  • National Key R&D Project of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Guangdong Province
  • Shenzhen Technology Innovation Commission
  • Shenzhen Engineering Laboratory for Diagnosis & Treatment Key Technologies of Interventional Surgical Robots

Zitieren

APA

Li, T., Zeng, Q., Li, J., Qian, C., Yu, H., Lu, J., Zhang, Y., & Zhou, S. (2024). An Adaptive Control Method and Learning Strategy for Ultrasound-Guided Puncture Robot. Electronics, 13(3), 580. https://doi.org/10.3390/electronics13030580

Vancouver

Li T, Zeng Q, Li J, Qian C, Yu H, Lu J, et al. An Adaptive Control Method and Learning Strategy for Ultrasound-Guided Puncture Robot. Electronics. 2024;13(3):580. doi:10.3390/electronics13030580

BibTeX
@article{Li2024,
  author = {Li, Tao and Zeng, Quan and Li, Jinbiao and Qian, Cheng and Yu, Hanmei and Lu, Jian and Zhang, Yi and Zhou, Shoujun},
  title = {An Adaptive Control Method and Learning Strategy for Ultrasound-Guided Puncture Robot},
  journal = {Electronics},
  year = {2024},
  volume = {13},
  number = {3},
  pages = {580},
  doi = {10.3390/electronics13030580}
}
Kostenlos starten →