Inverter Fault Diagnosis for a Three-Phase Permanent-Magnet Synchronous Motor Drive System Based on SDAE-GAN-LSTM
Electronics · 08.10.2023 · 12 (19) · 4172
DOI: 10.3390/electronics12194172 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 08.10.2023. Verfasst von Li Feng und 3 weiteren Autor:innen. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D project, Chongqing Science and Technology Bureau, Open Research Project of the State Key Laboratory of Industrial Control Technology, Zhejiang University, China.
Abstract (Originalsprache)
In this study, a novel intelligent inverter fault diagnosis approach based on a stacked denoising autoencoder–generative adversarial network–long short-term memory (SDAE-GAN-LSTM) under an imbalanced sample is proposed for a three-phase permanent-magnet synchronous motor (PMSM) drive system. The proposed method can address the problem of unbalanced fault data samples and improve the accuracy of fault classification. Concretely speaking, firstly, the stacked denoising autoencoder (SDAE) is pre-trained to obtain the optimum decoder network. Afterward, a new generator of generative adversarial networks (GANs) is designed to generate high-quality samples by migrating the pre-trained optimal decoder network to the hidden layer and output layer of the generator of GANs. Additionally, a new model of long short-term memory (LSTM) based on the second discriminator of the GANs is presented for fault diagnosis. The generator of GANs is cross-trained using the reconstruction error gained by SDAE and the fault diagnosis error obtained by LSTM, resulting in the generation of high-quality samples for fault discrimination. Simulation and experimental results demonstrate the effectiveness of the proposed fault diagnosis approach, and the average fault identification accuracy reaches 98.63%.
Förderung
- National Key R&D project
- Chongqing Science and Technology Bureau
- Open Research Project of the State Key Laboratory of Industrial Control Technology, Zhejiang University, China
- Equipment research project in advance
- Science and Technology Research Program of Chongqing Municipal Education Commission
- Postgraduate Research Innovation Project of Chongqing Jiaotong University
Zitieren
APA
Feng, L., Luo, H., Xu, S., & Du, K. (2023). Inverter Fault Diagnosis for a Three-Phase Permanent-Magnet Synchronous Motor Drive System Based on SDAE-GAN-LSTM. Electronics, 12(19), 4172. https://doi.org/10.3390/electronics12194172
Vancouver
Feng L, Luo H, Xu S, Du K. Inverter Fault Diagnosis for a Three-Phase Permanent-Magnet Synchronous Motor Drive System Based on SDAE-GAN-LSTM. Electronics. 2023;12(19):4172. doi:10.3390/electronics12194172
BibTeX
@article{Feng2023,
author = {Feng, Li and Luo, Honglin and Xu, Shuiqing and Du, Kenan},
title = {Inverter Fault Diagnosis for a Three-Phase Permanent-Magnet Synchronous Motor Drive System Based on SDAE-GAN-LSTM},
journal = {Electronics},
year = {2023},
volume = {12},
number = {19},
pages = {4172},
doi = {10.3390/electronics12194172}
}
EUVIMED