Heavy Ion Induced Degradation Investigation on 4H-SiC JBS Diode with Different P+ Intervals
Electronics · 06.05.2023 · 12 (9) · 2133
DOI: 10.3390/electronics12092133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 06.05.2023. Verfasst von Zhikang Wu und 9 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China under Grant.
Abstract (Originalsprache)
The heavy ion radiation response and degradation of SiC junction barrier Schottky (JBS) diodes with different P+ implantation intervals (S) are studied in detail. The experimental results show that the larger the S, the faster the reverse leakage current increases, and the more serious the degradation after the experiment. TCAD simulation shows that the electric field of sensitive points directly affects the degradation rate of devices with different structures. The large transient energy introduced by the heavy ion impact can induce a local temperature increase in the device resulting in lattice damage and the introduction of defects. The reverse leakage current of the degraded device is the same at low voltage as before the experiment, and is gradually dominated by space-charge-limited-conduction (SCLC) as the voltage rises, finally showing ballistic transport characteristics at high voltage.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China under Grant
Zitieren
APA
Wu, Z., Bai, Y., Yang, C., Li, C., Hao, J., Tian, X., Wang, A., Tang, Y., Lu, J., & Liu, X. (2023). Heavy Ion Induced Degradation Investigation on 4H-SiC JBS Diode with Different P+ Intervals. Electronics, 12(9), 2133. https://doi.org/10.3390/electronics12092133
Vancouver
Wu Z, Bai Y, Yang C, Li C, Hao J, Tian X, et al. Heavy Ion Induced Degradation Investigation on 4H-SiC JBS Diode with Different P+ Intervals. Electronics. 2023;12(9):2133. doi:10.3390/electronics12092133
BibTeX
@article{Wu2023,
author = {Wu, Zhikang and Bai, Yun and Yang, Chengyue and Li, Chengzhan and Hao, Jilong and Tian, Xiaoli and Wang, Antao and Tang, Yidan and Lu, Jiang and Liu, Xinyu},
title = {Heavy Ion Induced Degradation Investigation on 4H-SiC JBS Diode with Different P+ Intervals},
journal = {Electronics},
year = {2023},
volume = {12},
number = {9},
pages = {2133},
doi = {10.3390/electronics12092133}
}
EUVIMED