EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Refractive Index-Based Surface Plasmon Resonance Sensor for Bulk Sensing

Rajeev Kumar, Biswajit Brahma, Manoj Kumar, Javed Alam, Paolo Barsocchi, Akash Kumar Bhoi

Electronic Materials · 23.11.2026 · 7 (4) · 31

DOI: 10.3390/electronicmat7040031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronic Materials, online erschienen am 23.11.2026. Verfasst von Rajeev Kumar und 5 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we investigated the performance of surface plasmon resonance (SPR) sensors using three distinct plasmonic metals—silver (Ag), copper (Cu), and aluminum (Al)—along with a dielectric titanium dioxide (TiO2) layer of varying thicknesses (0–3 nm) and a Molybdenum Ditelluride (MoTe2) layer. The sensing performance of the proposed SPR sensor was optimized by varying the TiO2 thickness (0–3 nm) while maintaining a fixed MoTe2 layer. The optimized multilayer configuration exhibited enhanced RI sensing performance compared with the corresponding structures under the investigated conditions. Key metrics, including sensitivity (S), minimum reflectance (Rmin), full width at half maximum (FWHM), detection accuracy (DA), and figure of merit (FoM), were used to assess the sensor performance at two refractive indices (ns = 1.33 and 1.335). The findings show that adding a thin layer of TiO2 and MoTe2 improved the sensitivity for all metal configurations. Because of their narrow FWHM, Al-based sensors produce the sharpest resonance curves with the highest FoM (up to 102.89/RIU), whereas Ag-based sensors have the highest sensitivity, reaching up to 321.2°/RIU. Cu-based sensors provide performance that balances spectral resolution and sensitivity. Depending on the metal, the ideal TiO2 thickness varies, but 1–3 nm offers the best trade-off. These results show how to optimize an SPR sensor’s sensitivity by customizing metal–dielectric combinations. After suitable surface functionalization with selective recognition layers, the suggested multilayer SPR structure shows outstanding performance for bulk RI sensing and offers a promising platform for future biomolecular sensing applications.

Zitieren

APA

Kumar, R., Brahma, B., Kumar, M., Alam, J., Barsocchi, P., & Bhoi, A. K. (2026). Refractive Index-Based Surface Plasmon Resonance Sensor for Bulk Sensing. Electronic Materials, 7(4), 31. https://doi.org/10.3390/electronicmat7040031

Vancouver

Kumar R, Brahma B, Kumar M, Alam J, Barsocchi P, Bhoi AK. Refractive Index-Based Surface Plasmon Resonance Sensor for Bulk Sensing. Electronic Materials. 2026;7(4):31. doi:10.3390/electronicmat7040031

BibTeX
@article{Kumar2026,
  author = {Kumar, Rajeev and Brahma, Biswajit and Kumar, Manoj and Alam, Javed and Barsocchi, Paolo and Bhoi, Akash Kumar},
  title = {Refractive Index-Based Surface Plasmon Resonance Sensor for Bulk Sensing},
  journal = {Electronic Materials},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {31},
  doi = {10.3390/electronicmat7040031}
}
Kostenlos starten →