Kurz gefasst

Fachartikel in der Zeitschrift Electricity, online erschienen am 20.08.2026. Verfasst von Suzan Abdelhady und 2 weiteren Autor:innen. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Grid unreliability can compromise electricity supply in developing regions, yet comparative evidence on residential-district hybrid systems under consistent outage assumptions remains limited. This study compares four grid-connected architectures for a residential district in Egypt: wind/battery/grid, PV/wind/battery/grid, PV/battery/grid, and PV/wind/grid, using a simulation–optimization framework with net present cost (NPC) as the sole optimization objective. Supply adequacy, renewable fraction, grid interaction, and grid-related operational CO2 emissions were then assessed. Under baseline conditions, PV/wind/battery/grid was the minimum-NPC hybrid configuration, with an NPC of USD 481,851, LCOE of USD 0.0711/kWh, renewable fraction of 73.8%, unserved energy of 0.306 MWh/yr, and operational CO2 emissions of 139,533 kg/yr. Relative to grid-only supply, it reduced unserved energy by 98.5% and emissions by 65.0%, although grid-only had the lower NPC of USD 369,414. To distinguish fixed-design deterioration from adaptive redesign, baseline-optimal capacities were evaluated unchanged under a common severe grid-availability profile and compared with re-optimized counterparts. For the three battery-containing architectures with complete adaptive results, re-optimization reduced unserved energy by 73.2–97.2%, while resizing differed markedly. Among these architectures, wind/battery/grid had the lowest severe-condition NPC, only 0.63% below PV/wind/battery/grid. Deterministic ±10% sensitivity analysis retained PV/wind/battery/grid as the minimum-NPC architecture. Overall, baseline cost optimality, fixed-design transferability, and adaptation requirements are distinct, architecture-dependent planning considerations.

Zitieren

APA

Abdelhady, S., Shaban, A., & Al-Hinai, N. (2026). Techno-Economic and Reliability Assessment of Grid-Connected PV/Wind/Battery Hybrid Configurations for a Domestic District Under Unreliable Grid Conditions. Electricity, 7(3), 88. https://doi.org/10.3390/electricity7030088

Vancouver

Abdelhady S, Shaban A, Al-Hinai N. Techno-Economic and Reliability Assessment of Grid-Connected PV/Wind/Battery Hybrid Configurations for a Domestic District Under Unreliable Grid Conditions. Electricity. 2026;7(3):88. doi:10.3390/electricity7030088

BibTeX
@article{Abdelhady2026,
  author = {Abdelhady, Suzan and Shaban, Ahmed and Al-Hinai, Nasr},
  title = {Techno-Economic and Reliability Assessment of Grid-Connected PV/Wind/Battery Hybrid Configurations for a Domestic District Under Unreliable Grid Conditions},
  journal = {Electricity},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {88},
  doi = {10.3390/electricity7030088}
}