EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced Load Frequency Control in Multi-Area Hybrid Power Systems Using a 2-DOF Fractional-Order TID Controller with Artificial Ecosystem Optimization

Anas F. Abufedda, Momen Alattar, Khalid Masoud, Audih Alfaoury

Electricity · 23.07.2026 · 7 (3) · 73

DOI: 10.3390/electricity7030073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electricity, online erschienen am 23.07.2026. Verfasst von Anas F. Abufedda und 3 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Load frequency control (LFC) plays a critical role in maintaining frequency stability and regulating power transfer between interconnected areas subjected to continuous load variations. In multi-area systems, disturbances tend to propagate through interconnected tie-lines rather than remaining restricted locally, often leading to slower responses and weak coordination when conventional controllers are employed. In this paper, a two-degrees-of-freedom fractional-order differential integration (2DOF FO-TID) controller is proposed to improve both frequency regulation and dynamic interaction. The structure enables independent tuning of tracking and disturbance rejection, allowing greater flexibility in shaping system response. The controller parameters are optimally tuned by the Artificial Ecosystem Optimization (AEO) algorithm. The proposed approach is evaluated on a two-area hybrid thermal power system incorporating an SMES unit within the MATLAB/Simulink (R2022b) environment and compared with PID, FOPID, and TID controllers under identical conditions. The results indicate that, although some conventional controllers provide faster stabilization in one area, their performance in the interconnected area remains slower. In contrast, the proposed controller achieves more robust behavior across both areas, with the settling time of the second area reduced from about 25 s to nearly 11 s without degrading the response of the first area. These results highlight the importance of coordination in multi-area systems and demonstrate that the proposed approach enhances overall system performance and damping compared to conventional methods.

Zitieren

APA

Abufedda, A. F., Alattar, M., Masoud, K., & Alfaoury, A. (2026). Enhanced Load Frequency Control in Multi-Area Hybrid Power Systems Using a 2-DOF Fractional-Order TID Controller with Artificial Ecosystem Optimization. Electricity, 7(3), 73. https://doi.org/10.3390/electricity7030073

Vancouver

Abufedda AF, Alattar M, Masoud K, Alfaoury A. Enhanced Load Frequency Control in Multi-Area Hybrid Power Systems Using a 2-DOF Fractional-Order TID Controller with Artificial Ecosystem Optimization. Electricity. 2026;7(3):73. doi:10.3390/electricity7030073

BibTeX
@article{Abufedda2026,
  author = {Abufedda, Anas F. and Alattar, Momen and Masoud, Khalid and Alfaoury, Audih},
  title = {Enhanced Load Frequency Control in Multi-Area Hybrid Power Systems Using a 2-DOF Fractional-Order TID Controller with Artificial Ecosystem Optimization},
  journal = {Electricity},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {73},
  doi = {10.3390/electricity7030073}
}
Kostenlos starten →