A Framework for Integrating Virtualized PAC into Availability Model of a Digital Substation: An Exploratory Adaptation of Software Aging and Rejuvenation Model

Rizwan Rafique Syed, Hans Kristian Høidalen

Electricity · 25.05.2026 · 7 (2) · 47

DOI: 10.3390/electricity7020047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electricity, online erschienen am 25.05.2026. Verfasst von Rizwan Rafique Syed und 1 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Council of Norway.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Software aging and the corresponding need for system rejuvenation are well-established concepts in computer science. As virtualization technologies are increasingly adopted within electric power utility infrastructures, early investigation into Software Aging and Rejuvenation (SAR) models, aging indicators, and empirical data collection becomes essential. Given the critical role of the electric power grid and the high dependability requirements of the protection and control systems that support its operation, proactive research in this area is timely and necessary. Motivated by this need, this work proposes a hierarchical framework that integrates an SAR model into the Reliability Block Diagram (RBD) representation of a Digital Substation Automation System (DSAS). The analysis shows that, for the selected parameter set, incorporating SAR into the VPAC reliability model results in higher estimated failure rates and increased annual downtime relative to hardware-only models. When combined with substation primary system indices, however, the overall reliability indices remain largely unchanged, aside from reduced outage duration attributed to improved switching performance enabled by the DSAS architecture. Further examination reveals that the limited influence of SAR is primarily due to the lack of historical failure-mode data for the secondary system. Availability of such empirical data is expected to significantly affect combined reliability indices and improve the accuracy of reliability evaluations. This highlights the importance of systematic data collection and aging-indicator analysis as utility infrastructures transition toward virtualized and software-dependent architectures.

Förderung

  • Research Council of Norway

Zitieren

APA

Syed, R. R., & Høidalen, H. K. (2026). A Framework for Integrating Virtualized PAC into Availability Model of a Digital Substation: An Exploratory Adaptation of Software Aging and Rejuvenation Model. Electricity, 7(2), 47. https://doi.org/10.3390/electricity7020047

Vancouver

Syed RR, Høidalen HK. A Framework for Integrating Virtualized PAC into Availability Model of a Digital Substation: An Exploratory Adaptation of Software Aging and Rejuvenation Model. Electricity. 2026;7(2):47. doi:10.3390/electricity7020047

BibTeX
@article{Syed2026,
  author = {Syed, Rizwan Rafique and Høidalen, Hans Kristian},
  title = {A Framework for Integrating Virtualized PAC into Availability Model of a Digital Substation: An Exploratory Adaptation of Software Aging and Rejuvenation Model},
  journal = {Electricity},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {47},
  doi = {10.3390/electricity7020047}
}
Kostenlos starten →