EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automatic Under-Frequency Load Shedding with Sensitivity to Associated Load Type

Josué D. Builes-Quintero, Andrés F. Ángel-Ciro, Santiago Bustamante-Mesa, Sergio D. Saldarriaga-Zuluaga

Electricity · 01.04.2026 · 7 (2) · 29

DOI: 10.3390/electricity7020029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electricity, online erschienen am 01.04.2026. Verfasst von Josué D. Builes-Quintero und 3 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institución Universitaria Pascual Bravo.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing penetration of low-inertia renewable energy sources and distributed generation has significantly reduced system inertia, making frequency stability a critical challenge in modern power systems. Traditional Under-Frequency Load Shedding (UFLS) schemes often fail to adapt to varying operating conditions and load behaviors, leading to either insufficient or excessive disconnections. This paper presents an optimization-based UFLS scheme that integrates dynamic simulations in DIgSILENT PowerFactory with Python programming through the Particle Swarm Optimization (PSO) algorithm. The proposed methodology optimizes key UFLS parameters—frequency thresholds, intentional delays, and load-shedding percentages—under different ZIP load model configurations (constant power, constant current, and constant impedance). Simulation results on the IEEE 39-bus test system demonstrate that the type of load model has a significant impact on frequency recovery performance and the total amount of load shed. The constant power model achieved system stability with the lowest load disconnection, whereas the constant impedance model required a greater amount of shedding to restore nominal frequency. The results validate the effectiveness of the proposed optimization tool and highlight the importance of considering load characteristics in UFLS design to enhance operational reliability and resilience in modern power systems.

Förderung

  • Institución Universitaria Pascual Bravo

Zitieren

APA

Builes-Quintero, J. D., Ángel-Ciro, A. F., Bustamante-Mesa, S., & Saldarriaga-Zuluaga, S. D. (2026). Automatic Under-Frequency Load Shedding with Sensitivity to Associated Load Type. Electricity, 7(2), 29. https://doi.org/10.3390/electricity7020029

Vancouver

Builes-Quintero JD, Ángel-Ciro AF, Bustamante-Mesa S, Saldarriaga-Zuluaga SD. Automatic Under-Frequency Load Shedding with Sensitivity to Associated Load Type. Electricity. 2026;7(2):29. doi:10.3390/electricity7020029

BibTeX
@article{BuilesQuintero2026,
  author = {Builes-Quintero, Josué D. and Ángel-Ciro, Andrés F. and Bustamante-Mesa, Santiago and Saldarriaga-Zuluaga, Sergio D.},
  title = {Automatic Under-Frequency Load Shedding with Sensitivity to Associated Load Type},
  journal = {Electricity},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {29},
  doi = {10.3390/electricity7020029}
}